6.
Operation
6.1. Switching the device on/off
Press the
key to switch on the device. The LED in-
dicator will light up.
Press the
key again to switch the device off. The
display will disappear and the indicator LED will light
up orange.
The heating indicator
heating up. As soon as the desired temperature has
stabilised, it switches itself on or off, depending on
heating requirements.
NOTE
Any settings that have been configured will remain
applied even if the power supply is interrupted.
6.2. Manual operation
Press the
key to switch between the manual oper-
ation modes:
Comfort
ECO
Frost protection
6.3. Setting the Comfort temperature
Use the + or – keys to increase or reduce the Comfort
temperature as required.
In Comfort operation, the temperature can be ad-
justed based on use by means of the energy effi-
ciency indicator.
6.4. Setting the ECO temperature
Press the
key again until ECO is displayed. Briefly
press the + or – keys to display the temperature.
Press the
key for 3 s, until the ECO temperature
flashes. Use the + or – keys to increase or reduce the
temperature. Press the
ting.
ECO mode is recommended for maximum savings
during a short absence (less than 24 h). Reduce the
room temperature by around 3.5 °C below the Com-
fort temperature.
The maximum temperature that can be set for the
ECO temperature is 19 °C.
6.5. Automatic operation
Mode for planning your heating times and heating
temperatures: Programming of Comfort and ECO
modes, preferred temperature, window monitoring.
Factory setting: Preferred temperature 19 °C, window
monitoring activated.
Programming siehe Abschnitt „6.11. Internal pro-
gramming".
EN-6
shows that the device is
key for 3 s to save the set-
MFP 051E, MFP 101E, MFP 151E, MFP 201E
6.6. Frost protection mode
Press the
key again until
tection mode is displayed.
For maximum savings during a long absence (longer
than 24 hours) to keep the room frost-free.
6.7. Window monitoring
Press the
key for 1 s to activate window monitor-
ing. The symbol
off as soon as the room temperature drops sharply,
e.g. due to an open window or an open door. The sym-
bol
and the green LED indicator will flash. Press the
key to switch the device on again.
Press the
key for 1 s to deactivate window moni-
toring. The symbol
6.8. Easy key lock
Locking
Unlocking
6.9. Key lock with numerical code
Lock key entry with a four-digit numerical code.
Locking
Press the + and – keys simultaneously for 10 s.
CLEF 1 is displayed after 3 s. After a further 7 s,
CODE flashes and the symbol
Confirm with the
will flash.
Use the + or – keys to select the desired digit for
the first position.
Confirm with the
tion will flash.
Proceed in the same way for all four code positions.
After confirming the fourth position, the set tem-
perature and the symbol
2302/A
indicating frost pro-
is displayed. The device switches
is not displayed.
Press the + and – keys simultaneously
for 3 s until CLEF 1 and the symbol
are displayed.
The device is now protected against
unauthorised access to the settings
and only the on/off key can be oper-
ated.
Press the + and – keys simultaneously
for 3 s until CLEF 0 is displayed and the
symbol
disappears.
is displayed.
key. The first code position
key. The second code posi-
will be displayed.