MONTAGE- UND BETRIEBSANLEITUNG:
Device specific
Index
Name
dec (hex)
1 (0x01)
Alert delay time
[ms]
2 (0x02)
Automatic alert
reset time [ms]
14905 (0x3A39)
Platform version
14908 (0x3A3C)
Sensor head
firmware version
16384 (0x4000)
Qint.3 SP1 / SP2
1 (0x01)
SP1
2 (0x02)
SP2
16385 (0x4001)
Qint.3 Configuration Record
1 (0x01)
Switchpoint Logic
2 (0x02)
Switchpoint Mode
3 (0x03)
Switchpoint
Hysteresis
16386 (0x4002)
Qint.4 SP1 / SP2
1 (0x01)
SP1
2 (0x02)
SP2
16387 (0x4003)
Qint.4 Configuration Record
1 (0x01)
Switchpoint Logic
2 (0x02)
Switchpoint Mode
3 (0x03)
Switchpoint
Hysteresis
16388 (0x4004)
Qint.5 SP1 / SP2
1 (0x01)
SP1
2 (0x02)
SP2
16389 (0x4005)
Qint.5 Configuration Record
1 (0x01)
Switchpoint Logic
2 (0x02)
Switchpoint Mode
3 (0x03)
Switchpoint
Hysteresis
16390 (0x4006)
Qint.6 SP1 / SP2
1 (0x01)
SP1
2 (0x02)
SP2
16391 (0x4007)
Qint.6 Configuration Record
1 (0x01)
Switchpoint Logic
2 (0x02)
Switchpoint Mode
3 (0x03)
Switchpoint
Hysteresis
16392 (0x4008)
Qint.7 SP1 / SP2
1 (0x01)
SP1
2 (0x02)
SP2
1 ro = read only, wo = write only, rw = read/write
2 COM values specify the bitrate (see IO-Link specification): COM1 (4,8 kbit/s), COM2 (38,4 kbit/s), COM3 (230,4 kbit/s)
Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com
MFS02-S-KHC-IL
Format
Length
(Offset)
Bit (32)
32 Bit
Bit (0)
32 Bit
String
32 Byte
String
32 Byte
Record
4 Byte
Bit (16)
16 Bit
Bit (0)
16 Bit
4 Byte
Bit (24)
8 Bit
Bit (16)
8 Bit
Bit (0)
16 Bit
Record
4 Byte
Bit (16)
16 Bit
Bit (0)
16 Bit
4 Byte
Bit (24)
8 Bit
Bit (16)
8 Bit
Bit (0)
16 Bit
Record
4 Byte
Bit (16)
16 Bit
Bit (0)
16 Bit
4 Byte
Bit (24)
8 Bit
Bit (16)
8 Bit
Bit (0)
16 Bit
Record
4 Byte
Bit (16)
16 Bit
Bit (0)
16 Bit
4 Byte
Bit (24)
8 Bit
Bit (16)
8 Bit
Bit (0)
16 Bit
Record
4 Byte
Bit (16)
16 Bit
Bit (0)
16 Bit
Access
Default /
1
Value
rw
0
rw
-1
ro
ro
rw
rw
0
rw
0
rw
rw
0
rw
rw
70
rw
rw
0
rw
0
rw
rw
0
rw
0
rw
70
rw
rw
0
rw
0
rw
rw
0
rw
0
rw
70
rw
rw
0
rw
0
rw
rw
0
rw
0
rw
70
rw
rw
0
rw
0
Value / Range
Remark [Unit]
0...1000000 = Alert
delay time between
0 and 1000s
-1...1000000 =
Automatic alert
reset time between
0
and 1000s, -1
deactivates the
automatic alert
reset.
Setpoint 1
Setpoint 2
0 = Not inverted
1 = Inverted
0 = Deactivated
1 = Single Point Mode
2 = Window Mode
3 = Two Point Mode
129 = Cylinder Switch Mode
131 = Grip
[×10μm]
Setpoint 1
Setpoint 2
0 = Not inverted
1 = Inverted
0 = Deactivated
1 = Single Point Mode
2 = Window Mode
3 = Two Point Mode
129 = Cylinder Switch Mode
[×10μm]
Setpoint 1
Setpoint 2
0 = Not inverted
1 = Inverted
0 = Deactivated
1 = Single Point Mode
2 = Window Mode
3 = Two Point Mode
129 = Cylinder Switch Mode
×10μm]
Setpoint 1
Setpoint 2
0 = Not inverted
1 = Inverted
0 = Deactivated
1 = Single Point Mode
2 = Window Mode
3 = Two Point Mode
129 = Cylinder Switch Mode
[×10μm]
Setpoint 1
Setpoint 2