Herunterladen Diese Seite drucken

Zimmer MFS02-S-KHC-IL Montage- Und Betriebsanleitung Seite 29

Magnetfeldsensor mit io-link und analogausgang

Werbung

MONTAGE- UND BETRIEBSANLEITUNG:
17.1.4 Service data
The following ISDUs will not be saved via Data-Storage: Teach-in Channel, Device Specific Name, Find Me, Total actuator travel [sum m] and Cycle count [sum]
IO-Link specific
Index
Name
dec (hex)
12 (0x0C)
Device Access
Locks
1 (0x01)
Parameter Write
Access
2 (0x02)
Data Storage
3 (0x03)
Local Parameter-
ization
4 (0x04)
Local User Interface Bit (3)
16 (0x10)
Vendor Name
17 (0x11)
Vendor Text
18 (0x12)
Product Name
19 (0x13)
Product ID
20 (0x14)
Product Text
21 (0x15)
Serial Number
22 (0x16)
Hardware Revision
23 (0x17)
Firmware Revision
24 (0x18)
Application-specific
Tag
36 (0x24)
Device Status
ro = read only, wo = write only, rw = read/write
1
COM values specify the bitrate (see IO-Link specification): COM1 (4,8 kbit/s), COM2 (38,4 kbit/s), COM3 (230,4 kbit/s)
2
IO-Link specific
Index
Name
dec (hex)
37 (0x25)
Detailed Device
Status
40 (0x28)
PD Input
Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com
MFS02-S-KHC-IL
Format
Length
(Offset)
Record
2 Byte
Bit (0)
1 Bit
Bit (1)
1 Bit
Bit (2)
1 Bit
1 Bit
String
64 Byte
String
64 Byte
String
64 Byte
String
64 Byte
String
64 Byte
String
16 Byte
String
64 Byte
String
64 Byte
String
32 Byte
UInt
8 Bit
Format
Length
(Offset)
Array
192 Byte
PD In
4 Byte
Access1 Default
Value
rw
The access to the device parameters can be restricted by setting appropriate
flags within this parameter
rw
true = Locked
false = Unlocked
rw
true = Locked
false = Unlocked
rw
true = Locked
false = Unlocked
rw
true = Locked
false = Unlocked
ro
Zimmer GmbH
ro
www.zimmer-group.com
ro
MFS
ro
MFS02-S-KHC-IL
ro
Magnetfeldsensor mit IO-Link und Analogausgang
ro
Unique, vendor-specific identifier of the individual device.
ro
Unique, vendor-specific identifier of the hardware revision of the individual
device
ro
Unique, vendor-specific identifier of the firmware revision of the individual
device.
rw
**
ro
0 = Device is OK
1 = Maintenance required
2 = Out of specification
3 = Functional check
4 = Failure
Access1
Default
Value
ro
Octet String [64]
ro
Last valid process input data of the device.
Value / Range
Remark [Unit]
This lock prevents the write access to all read/write
parameters of the device except for the parameter
'Device Access Locks'.
This lock prevents the write access to the device
parameters via the data storage mechanism.
This lock prevents the device settings from being
changed via local operating elements on the
device.
This lock prevents the access to the device settings
and display via a local user interface. The user
interfaceis disabled.
The vendor name that is assigned to a Vendor ID.
Additional information about the vendor
Complete product name
Possibility to mark a device with user- or applica-
tion-specific information
Indicator for the current device condition and
diagnosis state.
Value / Range
Remark [Unit]
List of all currently pending events in the device.
29

Werbung

loading