Herunterladen Diese Seite drucken

Zimmer MFS02-S-KHC-IL Montage- Und Betriebsanleitung Seite 31

Magnetfeldsensor mit io-link und analogausgang

Werbung

MONTAGE- UND BETRIEBSANLEITUNG:
Device specific
Index
Name
dec (hex)
3 (0x03)
Switchpoint Hysteresis
64 (0x40)
Device Specific Name
67 (0x43)
Process data user
definition
1 (0x01)
Bit 0
2 (0x02)
Bit 1
3 (0x03)
Bit 2
4 (0x04)
Bit 3
5 (0x05)
Bit 4
6 (0x06)
Bit 5
7 (0x07)
Bit 6
8 (0x08)
Bit 7
120 (0x78)
Process data select
121 (0x79)
Pin 2 configuration
170 (0xAA)
Switchpoint width [x10μm] Record
1 (0x01)
Qint.1 width
2 (0x02)
Qint.2 width
3 (0x03)
Qint.3 width
4 (0x04)
Qint.4 width
5 (0x05)
Qint.5 width
6 (0x06)
Qint.6 width
7 (0x07)
Qint.7 width
8 (0x08)
Qint.8 width
171 (0xAB)
Switchpoint tolerance
[x10μm]
1 (0x01)
Qint.1 tolerance
2 (0x02)
Qint.2 tolerance
3 (0x03)
Qint.3 tolerance
204 (0xCC)
Find Me
256 (0x100)
Position [x10μm]
257 (0x101)
Position offset [x10μm]
260 (0x104)
Detection range [x10μm]
1 (0x01)
Minimal position
2 (0x02)
Maximal position
261 (0x105)
Current position repeat-
ability [mm]
265 (0x109)
Position noise limit for
application range [mm]
4356 (0x1104)
Operating hours
1 (0x01)
Total
2 (0x02)
Since last reset
3 (0x03)
Since startup
4357 (0x1105)
Power cycles
1 (0x01)
Total
2 (0x02)
Since last reset
1 ro = read only, wo = write only, rw = read/write
2 COM values specify the bitrate (see IO-Link specification): COM1 (4,8 kbit/s), COM2 (38,4 kbit/s), COM3 (230,4 kbit/s)
Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com
MFS02-S-KHC-IL
Format
Length
Access
Default
1
(Offset)
Value
Bit (0)
16 Bit
rw
70
String
32 Byte
rw
***
Record
8 Byte
rw
Define the contents of the process data
Bit (56)
8 Bit
rw
1
Bit (48)
8 Bit
rw
2
Bit (40)
8 Bit
rw
3
Bit (32)
8 Bit
rw
4
Bit (24)
8 Bit
rw
5
Bit (16)
8 Bit
rw
6
Bit (8)
8 Bit
rw
7
Bit (0)
8 Bit
rw
8
UInt
8 Bit
rw
0
UInt
8 Bit
rw
36
16 Byte
rw
Switchpoint width
Bit
16 Bit
rw
200
(112)
Bit (96)
16 Bit
rw
200
Bit (80)
16 Bit
rw
200
Bit (64)
16 Bit
rw
200
Bit (48)
16 Bit
rw
200
Bit (32)
16 Bit
rw
200
Bit (16)
16 Bit
rw
200
Bit (0)
16 Bit
rw
200
Record
6 Byte
rw
Switchpoint tolerance
Bit (32)
16 Bit
rw
100
Bit (16)
16 Bit
rw
100
Bit (0)
16 Bit
rw
100
UInt
8 Bit
rw
0
Int
16 Bit
ro
Current position [x10μm]
Int
16 Bit
rw
0
Record
4 Byte
rw
Bit (16)
16 Bit
rw
-2500
Bit (0)
16 Bit
rw
-2500
Float
4 Byte
ro
[mm]
Float
4 Byte
rw
0.3
Record
12 Byte
ro
Operating Hours data
Bit (64)
32 Bit
ro
[h]
Bit (32)
32 Bit
ro
[h]
Bit (0)
32 Bit
ro
[h]
Record
8 Byte
ro
Power Cycles data
Bit (32)
32 Bit
ro
Bit (0)
32 Bit
ro
Value / Range
[×10μm]
0 = Set bit to constant 0
1 = Qint.1
2 = Qint.2
3 = Qint.3
4 = Qint.4
5 = Qint.5
6 = Qint.6
7 = Qint.7
8 = Qint.8
60 = Group alert: Cycle time
65 = Direct alert: Operating hours max.
68 = Direct alert: Power cycles max.
69 = Direct alert: Cycle count max.
90 = Direct alert: Total actuator travel max.
Compare value range in subindex 1
Compare value range in subindex 1
Compare value range in subindex 1
Compare value range in subindex 1
Compare value range in subindex 1
Compare value range in subindex 1
Compare value range in subindex 1
0 = Measurement value (2 Bytes) + Scale (1 Byte) + 8xQints/Alerts (1 Byte)
0 = Deactivated
36 = Qint.2
0...1000
0...1000
0...1000
0...1000
0...1000
0...1000
0...1000
0...1000
[x10μm]
[x10μm]
[x10μm]
0 = Stop FindMe
1 = LED flash
-27500...27500
-30000...30000
-30000...30000
[mm]
Remark [Unit]
Content of process data bit 0
Content of process data bit 1
Content of process data bit 2
Content of process data bit 3
Content of process data bit 4
Content of process data bit 5
Content of process data bit 6
Content of process data bit 7
[x10μm]
[x10μm]
[x10μm]
[x10μm]
[x10μm]
[x10μm]
[x10μm]
[x10μm]
Offset that is added to the current
position [x10μm]
[x10μm]
[x10μm]
31

Werbung

loading