Herunterladen Diese Seite drucken

Zimmer MFS02-S-KHC-IL Montage- Und Betriebsanleitung Seite 30

Magnetfeldsensor mit io-link und analogausgang

Werbung

MONTAGE- UND BETRIEBSANLEITUNG:
Device specific
Index
Name
dec (hex)
13 (0x0D)
Profile Characteristic
1 (0x01)
Profile Identifier
2 (0x02)
Profile Identifier
3 (0x03)
Profile Identifier
14 (0x0E)
PDInput descriptor
15 (0x0F)
PDOutput descriptor
25 (0x19)
Function Tag
26 (0x1A)
Location Tag
58 (0x3A)
Teach-in Channel
59 (0x3B)
Teach-in Result
1 (0x01)
State
2 (0x02)
Flag SP1 TP1
3 (0x03)
Flag SP1 TP2
4 (0x04)
Flag SP2 TP1
5 (0x05)
Flag SP2 TP2
60 (0x3C)
Qint.1 SP1 / SP2
1 (0x01)
SP1
2 (0x02)
SP2
61 (0x3D)
Qint.1 Configuration
1 (0x01)
Switchpoint Logic
2 (0x02)
Switchpoint Mode
3 (0x03)
Switchpoint Hysteresis
62 (0x3E)
Qint.2 SP1 / SP2
1 (0x01)
SP1
2 (0x02)
SP2
63 (0x3F)
Qint.2 Configuration
1 (0x01)
Switchpoint Logic
2 (0x02)
Switchpoint Mode
ro = read only, wo = write only, rw = read/write
1
COM values specify the bitrate (see IO-Link specification): COM1 (4,8 kbit/s), COM2 (38,4 kbit/s), COM3 (230,4 kbit/s)
2
30
Zimmer GmbH • Im Salmenkopf 5 •  77866 Rheinau, Germany •  +49 7844 9138 0 • www.zimmer-group.com
Format
Length
Access
1
(Offset)
Record
6 Byte
ro
Bit (32)
16 Bit
ro
Bit (16)
16 Bit
ro
Bit (0)
16 Bit
ro
Array
3 Byte
ro
Array
3 Byte
ro
String
32 Byte
rw
String
32 Byte
rw
UInt
8 Bit
rw
Record
1 Byte
ro
Bit (0)
4 Bit
ro
Bit (4)
1 Bit
ro
Bit (5)
1 Bit
ro
Bit (6)
1 Bit
ro
Bit (7)
1 Bit
ro
Record
4 Byte
rw
Bit (16)
16 Bit
rw
Bit (0)
16 Bit
rw
Record
4 Byte
rw
Bit (24)
8 Bit
rw
Bit (16)
8 Bit
rw
Bit (0)
16 Bit
rw
Record
4 Byte
rw
Bit (16)
16 Bit
rw
Bit (0)
16 Bit
rw
Record
4 Byte
rw
Bit (24)
8 Bit
rw
Bit (16)
8 Bit
rw
MFS02-S-KHC-IL
Default
Value / Range
Value
10
49
16384
Octet String [1]
Octet String [1]
***
Function Tag
***
Function Tag
0
0 = Default Qint (Qint.1)
1 = Qint.1
2 = Qint.2
3 = Qint.3
4 = Qint.4
5 = Qint.5
6 = Qint.6
7 = Qint.7
8 = Qint.8
Teach-in result provides feedback on the status and the results of the teach-in activities
0
0 = IDLE
1 = SP1 SUCCESS
2 = SP2 SUCCESS
3 = SP12 SUCCESS
4 = WAIT FOR COMMAND
5 = BUSY
7 = ERROR
false
true
false
false
true
false
false
true
false
false
true
false
0
Setpoint 1
0
Setpoint 2
0
0 = Not inverted
1 = Inverted
0
0 = Deactivated
1 = Single Point Mode
2 = Window Mode
3 = Two Point Mode
129 = Cylinder Switch Mode
130 = Move
131 = Grip
70
[×10μm]
0
Setpoint 1
0
Setpoint 2
0
0 = Not inverted
1 = Inverted
0
0 = Deactivated
1 = Single Point Mode
2 = Window Mode
3 = Two Point Mode
129 = Cylinder Switch Mode
130 = Move
131 = Grip
Remark [Unit]
The Qint channel that is going to
be teached

Werbung