Cleaning, Care & Maintenance
Switch off and disconnect from the power supply before cleaning.
Clean the interior of the appliance as often as possible.
Do not use abrasive cleaning agents. These can leave harmful residues.
Clean the door seal with water only.
Always wipe dry after cleaning.
A POLAR agent or qualified technician must carry out repairs if required.
If left unused for any length of time, store the appliance with the door ajar.
Auto Defrost
Periodically the appliance will run an automatic defrost cycle to prevent any ice build-up.
Troubleshooting
If your POLAR appliance develops a fault, please check the following table before making a call to the
Helpline or your POLAR dealer.
Fault
The appliance is not
The unit is not switched on
working
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
The appliance
Too much ice on the condenser
turns on, but the
Condenser blocked with dust
temperature is too
Doors are not shut properly
high/low
Appliance is located near a heat
source or air flow to the condenser
is being interrupted
Ambient temperature is too high
Appliance is overloaded
The appliance is
Loose nut/screw
unusually loud
The appliance has not been installed
in a level or stable position
Technical Specifications
Model
Voltage
Power Current
DB848
220-240V
60W
50Hz
DB848_ML_A5_v1_20191205.indb 5
Probable Cause
Temperature
Capacity
Range
(litres)
0.3A
2°C - 8°C
30
Solution
Check the unit is plugged in correctly and
switched on
Call POLAR agent or qualified Technician
Replace the fuse
Check power supply
Call POLAR agent or qualified Technician
Defrost the appliance
Call POLAR agent or qualified Technician
Check doors are shut and seals are not
damaged
Move the refrigerator to a more suitable
location
Increase ventilation or move appliance to a
cooler position
Reduce the amount stored in the appliance
Check and tighten all nuts and screws
Check installation position and change if
necessary
Dimensions
Refrigerant
H x W x D mm
R717 230g
530 x 415 x 400
UK
Weight
(kg)
14
5