Herunterladen Diese Seite drucken

EuroLite PAR-64 RGB DMX Farbwechsler Bedienungsanleitung Seite 19

Vorschau ausblenden Andere Handbücher für PAR-64 RGB DMX Farbwechsler:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

INSTALLATION
Installing/Replacing the lamps
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 20 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
For the installation, you need three A1 230V/500W GY-9.5 lamps.
During the operation, the lamp reaches temperatures of up to >1000° C.
Procedure:
Step 1: Unscrew the fixation screws on the outside housing.
Step 2: Remove the lens-colorfilter-unit using the mini brackets.
Step 3: If replacing the lamp, remove the old lamp from the lamp-socket.
Step 4: Insert the new A1 230V/500W GY-9.5 lamp into the lamp-socket.
Step 5: Replace the lens-colorfilter-unit and tighten the screws.
Overhead rigging
The installation of the projector has to be built and constructed in a way that it can hold 10 times the weight
for 1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
This secondary safety attachment must be constructed in a way that no part of the installation can fall down
if the main attachment fails.
When rigging, derigging or servicing the fixture staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.
DANGER TO LIFE!
Only install the lamps with the device switched off!
Unplug from mains before!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
Do not operate this device with opened lens-colorfilter-unit!
CAUTION!
19/48
00018983.DOC, Version 1.0

Werbung

loading