Starting up the device
Starting up the device
Before the device can be used, the following steps must be carried out:
■ Connect the motor cable to the intended junction or switch box
■ Carry out a test run
■ Mount the roller shutter curtain on the winding shaft
■ Set the upper and lower terminal stop point.
Connecting the device
Connection of the tubular motor to the mains power and all work on electrical
systems may only be carried out by a certified specialist electrician according to
the connection schematics contained in these instructions.
DANGER
Fatal electric shock due to coming into contact with live
components.
Do not carry out any connection work on the device when it is
connected to the current supply.
Make sure that the device is disconnected from the mains power
supply.
ATTENTION
Malfunctions or damage to the motor due to incorrect mains
voltage.
Compare the information on the model plate with that of your local
mains power supply.
Make sure that the device is only connected to a 230 V ~ 50 Hz
mains power supply.
ATTENTION
Short-circuit due to damaged cables.
Make sure that the cable cannot be damaged by moving parts in
the roller shutter box.
ATTENTION
Short-circuit due to water in the motor on routing cables
incorrectly.
Never route the cable vertically upwards.
Always route the cable in a loop.
Routing the cable in a loop enables the water to drip off (1.).
Connect the motor cable to the junction or switch box (2.) intended for this
purpose.
1.
22
1
2
3
4
2.
Item No.
Motor cable wire colour
1
Black
2
Brown
3
Blue
4
Green/yellow
Carry out a test run to check whether the motor's direction of rotation corresponds
to the switch position.
Operate the motor to lower the roller shutter.
Check whether the motor runs in the downwards direction.
If the motor does not run in the downwards direction, the cable assignment must
be changed.
Swap the motor cable's brown wire over with the black wire.
Make sure that the direction of rotation corresponds to the switch position.
In order to connect the device to a single-pin roller shutter switch,
observe the installation plan on page 28.
Installing the roller shutter curtain
The following prerequisites must be met in order to be able to install the roller
shutter curtain:
■ The roller shutter curtain must lie in the guide rail.
■ The tubular motor must be run all the way down.
ATTENTION
Damage to the tubular motor due to drilling or screwing.
Never drill or screw the winding shaft in the area of the tubular
motor.
Use only the holes available in the winding shaft to secure the roller
shutter curtain.
1. Approx. every 40 cm, slide a securing spring (1) onto the top slat of the roller
shutter curtain (2).
2. Insert the securing springs into the rectangular holes (3) in the winding shaft.
1
Function
Direction of rotation 1
Direction of rotation 2
Neutral conductor
Earth
2
1.
3
2.

Werbung