Herunterladen Diese Seite drucken

SFA SANIFLOOR 4 wedi-Serie Installationshinweise Seite 14

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 15
UK
1
DESCRIPTION
This suction pump is (manufactured in
a factory which is quality) certified to ISO
9001, ISO 14001. Installed and used
correctly, the unit will give consistent and
reliable service.
This device is not designed for
persons
(including
ren) with limited physical, sensory
or mental abilities, or those with
minimal experience and knowledge,
unless they are monitored and are
given the necessary instructions for
using the device, with the help of a
person responsible for their safety.
Monitor children and make sure they
do not play with the device.
2
APPLICATIONS
This device is a suction pump designed to
evacuate waste water from private dwel-
lings from a shower.
It consists of a shower gully (depending
on Sanifloor model) a water level detection
system and a suction pump.
3
INSTALLATION
The unit should be accessible for possible
service.
Be careful not to pinch or cut the electrical
wire that connects the shower to the gully
to the pump.
To optimise the latest technical develop-
ments concerning soundproofing incorpo-
rated into this unit, it is important to:
• position the tank so that it is not in
contact with a partition or wall of the room
• place the tank on a perfectly level
surface
• fix the discharge pipe correctly, with
distances of not more than one metre
between the fastenings
• Connect the discharge pipe to the gully
using cyanoacylate glue (ie. like Super
Glue)and tighten the hose clip. Check that
there are no leaks in the connections. Any
repair due to watertightness issue won't
be under guarantee.
CONNECTION TO THE ELECTRICAL
SUPPLY
The electrical installation
should be carried out by a
qualified person.
The unit should be connected to a fully
earthed electrical supply. All wiring must
conform to BS7671, 1992 requirements
for electrical installations. The unit requires
a 220/240V single phase AC 50 Hz supply
(UK specification). Do not connect the unit to
a conventional plug and socket. It must be
wired into a fused, unswitched, fixed
wiring connector fitted with a 5 amp
fuse. The wires in the mains lead are colou-
red in accordance with the following code:
Brown - Live
child-
Blue - Neutral
Green/Yellow – Earth
Warning: Ensure the electricity is
turned OFF at the main switch board
before wiring to connector.
All work on cable, pressure chamber
and motor should only be carried out
by a qualified Saniflo servicing agent,
as special tools are required.
4
COMMISSIONING THE
UNIT
Once electrical and plumbing connections
have been made, check that all seals, and
connections are watertight.
Check both the discharge pipework from
the unit and the shower.
6
FAULT FINDING / REMEDIES
IN ALL CASES, YOU MUST DISCONNECT
THE SUCTION PUMP FROM THE POWER SUPPLY
SYMPTOMS
• The motor does not activate
• The motor intermittently
activates
• Pump activates but water is not
being evacuated
• The motor operates normally, but
continues to run for a long time
• The unit stops
Fig 1
5
WARNING !!!
If away for a long period, we recommend
that you turn off the water supply.
CARE OF YOUR UNIT
instructions
removing the water level detection
module, use the manual override but-
ton (see fig.1) to pump out the water
that is inside the shower gully in
order to avoid any water penetration
into the electrical connection of the
level detection unit that will cause a
malfunction of the product.We recom-
mend that once a month the filter for the
shower gully is removed and cleaned to
avoid blockages.
PROBABLE CAUSES
• The electrical power supply
is not active
• The electrical power supply is
defective
• The motor or the water level
detector is defective
• The shower fitting is dripping
water into the tray
• The non-return valve is faulty
• Pump is not priming. Insufficient
water in reservoir
• The length or height of the
installation is over the
specification, or there are too
many bends/elbows
• The suction pump cover plate
is occluded
• Leak on pump or gully connections
• The unit has been running for
too long (thermal cut-out)
• Water level detector blocked
7
GUARANTEE
2 years guarantee as from its date of purchase subject to cor-
rect installation and correct use.
Warning : Do not dispose of solvents, paints (do not
wash paint brushes in sink), caustic, acid or other
chemicals into these products.
4
MAINTENANCE
To clean the shower gully,
carefully follow the manual
information.
REMEDIES
• Restore the electrical supply
• Check the electrical power
supply
• Check the water level detector
• Otherwise, ask an approved
repair agent to intervene
• Push at least 2 secondes on the
manual override button, see fig. 1
• Check the installation upstream
• Clean or replace the non-return
valve
• Unplug the unit, refill the pump
reservoir with water. (see section
7 A,B,C of the SANIFLOOR
manual instructions information))
• Check the installation
• Otherwise, ask an approved
repair agent to intervene
• Wait for reset, then ask an
approved repair agent to
intervene
• Check the water level detector,
clean it if necessary
Before

Werbung

loading