Herunterladen Diese Seite drucken

Weka Osby 2 Montage-, Bedienungs- Und Wartungsanleitung Seite 7

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

The warning signs
Extensive heating systems with 230 V mains voltage are located in the floor and wall elements.
After the infrared cabin has been set up in accordance with the assembly instructions, it is strictly
prohibited to install screws, nails, staples and the like in the cabin elements, as well to partially or
completely cover the heating surfaces (with towels or pillows, for example).
are to be attached according to figure 12 and figure 14.
Instructions for care
We recommend that you sit on sauna towels in the cabin so that the sweat does not run onto the wood parts.
Air out the cabin well after each session.
Also always ensure that the room in which the cabin is located is well ventilated.
The heating surfaces inside the cabin are maintenance free. They should not be covered or allowed to come
into contact with moisture. Stubborn stains on the wood can be removed with emery paper.
It is unavoidable that small amounts of resin will appear on the surface of the wood. The dry resin residues
can be removed with fine sandpaper.
Always use wood glue, never chemical adhesives, inside the cabin.
The bench and slatted floor should be thoroughly cleaned at least once per year outside of the cabin using a
soft brush and clear water.
Technical information
Prerequisite for connecting the infrared cabin: a socket with a separate 16 A fuse
For information on the operation and connection of the IR controller, see the assembly instructions of the
control panel and the IR controller.
The film sensor has already been fitted by us and is located in one of the rear wall elements.
The maximum wattage of the bulb used for cabin lighting should not be more than 40 W.
Ensure that the socket is accessible at all times.
If it needs to be replaced at a later date, the included mains cable must be ordered from weka customer
service.
In order to ensure all-pole disconnection of the unit from the mains, the plug must be removed from the
socket.
Two sockets for heating circuits 1-3 are located on the power element.
When connecting the radiant heater cables, it doesn't matter which of the two sockets
is used.
In order to prevent the glass door from sagging, screw down the Allen screw of the fittings tightly.
Door leaf
The adjustable eccentric, item 29, permits easy adjustment of the glass door leaf even at a later point in
time. The internal parts of the door fittings are removed, and the eccentric is rotated in the appropriate
direction.
During installation of the door grips, ensure that the metal grip piece is on the outside of the door.
Installation recommendations
Pre-drill all screw connections
in order to avoid damaging the wood parts.
The following symbol will remind you to do this
in the instructions:
Technical data:
- External dimensions W x D x H:
- Power:
- Mains voltage:
© Copyright HRB 3662
WARNING!
FIRE HAZARD, RISK OF FATAL INJURY!
Approx. 212x125x190 cm
3600W
230 V (50 Hz)
6
Technische Änderungen vorbehalten

Werbung

loading

Diese Anleitung auch für:

K000032671556.2012.00