Connection with the mains
Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
OPERATION
The device has two operating modes. It can be operated via DIP Switches or it can be run in DMX-controlled
mode.
After you connected the spot to the mains, the EUROLITE LED PAR-Spot starts running.
OPERATION VIA DIP SWITCHES
Auto Mode
In order to select Color change and Color fade, set DIP switch 9 and 10 to OFF. Set DIP switches 1 – 6 to
OFF as well.
Speed can be adjusted via DIP switches 7 and 8.
In order to select Static colors and flash, set DIP switch 9 and 10 to OFF. Set DIP switches 7 and 8 to OFF
as well.
DIP switch 1 to 3 control the color settings.
DIP switch 4 to 6 control the flash settings.