6. Operation
Install the equipment on a solid and level
surface.
Fill the pump housing with water via the water
filler screw (4). Filling the intake line will acce-
lerate the priming process.
All the shut-off devices in the discharge line
(spray nozzle, valves etc.) must be fully ope-
ned during intake in order to permit all air to
escape from the intake line.
Connect the mains cable.
Switch on the equipment with the power
switch (5) - water can be suctioned in for up
to 5 minutes (maximum suction height).
After finishing the work, switch off the equip-
ment with the power switch (5).
7. Replacing the power cable
Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
8. Cleaning, maintenance and
ordering of spare parts
The equipment is almost completely maintenance
free. In order to ensure a long service life, howe-
ver, we recommend that you regularly check and
care for the product.
Danger!
The equipment must be disconnected from the
power supply (pull the power plug) prior to perfor-
ming any maintenance.
8.1 Servicing
If the equipment becomes clogged, connect
the discharge line to the water line and dis-
connect the suction hose. Open the water
line. Switch on the equipment several times
for approx. two seconds. This should resolve
the majority of clog-related problems.
There are no parts inside the equipment
which require additional maintenance.
Anl_GC_GP_1046_N_GC_GP_1250_N_SPK7.indb 17
Anl_GC_GP_1046_N_GC_GP_1250_N_SPK7.indb 17
GB
8.2 Ordering replacement parts:
Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info
9. Disposal and recycling
The equipment is supplied in packaging to pre-
vent it from being damaged in transit. The raw
materials in this packaging can be reused or
recycled. The equipment and its accessories are
made of various types of material, such as metal
and plastic. Never place defective equipment in
your household refuse. The equipment should
be taken to a suitable collection center for proper
disposal. If you do not know the whereabouts of
such a collection point, you should ask in your
local council offi ces.
10. Storage
Store the equipment and accessories in a dark
and dry place at above freezing temperature. The
ideal storage temperature is between 5 and 30
°C. Store the electric tool in its original packaging.
If the pump is not going to be used for a long
time or has to be removed for the winter
months, rinse it out with water, empty it com-
pletely and allow it to dry.
The equipment must be completely drained
before it is subjected to frost.
After long stoppages, make sure the rotor
turns correctly by briefly switching the pump
on and off.