4.1 - Troubleshooting guide
Trouble
Power is off
Compressor
does not
work
The thermostat knob is not in the
proper position
The
temperature
inside the
chest freezer
is too high
Compressor
keeps on
working
The
temperature
inside is OK
The floor is not leveled
Too noisy
A screw in fan or condenser is loose
The refrigerating circuits touch each
other
Possibilities
The socket fuse is
broken
The connection
between plug and
socket is not good
No power arriving
to the freezer
Ice on the
evaporator is too
thick
The door is being
opened too
frequently
Too much food
has been stored
at once
The ambient
temperature is too
high, while the
thermostat is set
too low
The thermostat
does not work
Check up
Solutions
Check the fuse
Replace the fuse
Repair or replace
Check the plug
the plug or the
and the socket
socket
Make sure that
Check the house
the power mains
wirings and the
is on
electrical system
Rotate the
Check the
thermostat knob to
thermostat
the correct position
Check if the ice
is thicker than
Defrost regularly
6-8mm
Reduce the door
opening periods.
Take out some of
the food
Check that the
thermostat is set
Adjust the
at "5" or "6"
thermostat knob
position
Replace the
thermostat
Make sure that
Level the freezer
the freezer is
putting a pad or
correctly leveled
shims under castors
The screw is
Fix the screw tightly
loose
Separate the circuits
Remarks
Call a technician
Call an electrician
For normal use the
thermostat should be set to
"4"
Call a technician.