Herunterladen Inhalt Inhalt Diese Seite drucken

afx light BEAM1R-MKIII Bedienungsanleitung Seite 7

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

This time lighting hour
Error information
Reset fail, uart error
Pan reset fail
Tilt reset fail
Pan Hall error
Tilt Hall error
Motor Colour reset fail
Motor Gobo reset fail
Lamp control fail
lamp hours too long, pls re-
place
2.5 Advanced interface
Set a password to prevent non-authorized persons to operate the unit. Default password is "UP
DOWN UP DOWN". Press "Enter" to check the password
Option
Y Hall state
Color wheel hall state 0 means the magnet closure, 1 means the magnet stagger
Gobo wheel hall state 0 means the magnet closure, 1 means the magnet stagger
X coding disc state
Y coding disc state
X coding disc step va-
lue
Y coding disc step va-
lue
X calibration
Y calibration
Color wheel calibra-
Reset ca-
tion
libration
Gobo wheel calibra-
tion
Prism zoom calibra-
tion
Maximum
lighting
hour
Reset ligh-
ting hour
This time lighting hour (accurate to minute)
Instruction
Driver board doesn't respond. There is problem in the uart commu-
nication line of display board and driver board. Or the driver board
problem.
X photoelectric switch, or X Motor problem
Y photoelectric switch, or Y Motor problem
Problem in X Hall
Problem in Y Hall
There is problem in Color wheel hall, or Color wheel motor
There is problem in Gobo wheel hall, or Gobo wheel motor
Lamp light on or off fail, there is problem in ballast or lamp
The total lamp light hour over the Maximum lamp light hour in "high
class" menu. Remind the user change the lamp in time. And then
clear the lamp light hour in "high class", timer reset
Instruction
0 means the magnet closure, 1 means the magnet stagger
2digit, each digit corresponding to the photoelectricity
switch on the coding disc
2digit, each digit corresponding to the photoelectricity
switch on the coding disc
Running in positive direction, the step value adding, Run-
ning in negative direction, the step value reduced
Running in positive direction, the step value adding, Run-
ning in negative direction, the step value reduced
X Fine
Y Fine
Color wheel fine
Gobo wheel fine
Prism zoom fine
0-9999hours. The alarm sounded once over the maximum
lamp lighting hour
After clear the lamp light hour, timer reset
www.afx-light.com
Adjustment range:-128~+127,
+0 shows no adjustment
7