4. Use of the LiFePO4 Battery Pack
4.1 Charging
LiFePO4 batteries do not need to be recharged after each use, leaving them in a partially
charged state is not harmful to the battery
The battery can be charged with high charging current to shorten the charging time, max.
charging current per battery, see data sheet
If the BMS disconnects the battery due to low voltage to protect against deep discharge, the
battery should be recharged as soon as possible. Otherwise, the cells could be permanently
damaged
LiFePO4 batteries can be safely charged in the temperature range 0°C - 55°C
Charge with any IU charger that does not exceed a final charge voltage of 14.6V or with a
charger with LiFePO4 characteristics
The BMS switches the battery off if it gets too hot. When the temperature drops, it
automatically switches the battery back on
If necessary, the cells are balanced automatically during charging or during a standby phase
4.2 Discharging
Discharge up to 100% of capacity is possible, but a discharge of max. 90% is recommended
Safe discharge in the temperature range -20°C to 60°C
The BMS switches the battery off if it becomes too hot. When the temperature drops, it
automatically switches the battery back on