3.1 General
Please check the battery for external damage before installation. If there is visible damage,
do not install or operate the battery, please contact your vendor immediately
The battery must always be operated with an appropriate external fuse in the consumer
circuit
The battery can be installed in an upright, standing or lying position
The battery must be firmly and securely installed in the vehicle or system, in motorhomes
the existing mounting can very often be used
The connection poles and terminals must be covered after installation to protect against
short circuits, existing round pole terminals can be used
Never connect batteries with consumers switched on to avoid sparking
Do not expose battery to direct sunlight and install indoors, do not install near heat sources
Charge before commissioning, during transport the battery is only charged to 40-60%

3.2 Installation of several batteries in series or parallel connection

Caratec LiFePO4 batteries can be connected in series and/or parallel, please note:
Before installation, make sure that the batteries have max. 50mV voltage deviation from
each other, if this is not the case, charge both individually to 100%, then equalise by
discharging individually
When connected in series (max. 4 batteries), the voltage increases, but the capacity does
not increase
With parallel connection (max. 4 batteries) the capacity increases, the voltage does not
change. The currents for both charging and discharging increase accordingly
A circuit in which the batteries are connected both in series and in parallel is theoretically
possible, but is not recommended
In the case of series or parallel connection, the cable lengths of the positive and negative
cables should be the same for the connections between them. The cross-sections must also
be the same