The mains input & output terminal connector can be found on the bottom of the Multi, see
appendix A. The shore or mains cable must be connected to the connector with a three-
wire cable. Use a three-wire cable with a flexible core and a cross section of at least
1.5mm².
Procedure (see appendix A)
Proceed as follows to connect the AC cables:
The AC output cable can be connected directly to the male-connector. (the connector pulls
out!)
The terminal points are indicated clearly. From left to right: 'N' (neutral), earth, and 'L1'
(phase).
The AC input cable can be connected directly to the female-connector. (the connector pulls
out!)
The terminal points are indicated clearly. From left to right: 'L1' (phase), earth, and 'N'
(neutral).
Push the 'input' connector into the AC-in connector.
Push the 'output' connector into the AC-out connector.
11