3. Set-up, operation and shut-down.

3.1. Preparation for operation.
For remote control system start up you should follow these instructions:
1.
If necessary shorten the RC hose to the length of the used blasting hose.
2.
Connect the fittings provided in the package with RC hose. Connect RC hose to
distant control handle DMH from one side and TWINLINE line of the blasting machine
from another side.
ATTENTION!
DO NOT TIGHTEN UNIONS TOO MUCH, IN PARTICULAR THE UNIONS OF RC
HANDLE. IT CAN DAMAGE SOME COMPONENTS AND CAUSE AN AIR LEAK.
3.
Ensure that all connections are leak-proof.
4.
Ensure that all connections on the RC valve and RC handle DMH are connected
properly, and according to the color. Transverse joint will make the system non-
operational.
5.
Fix RC handle DMH to the blasting hose, using clamp bands right behind the nozzle holder.
6.
We recommend to connect a twin hose Twinline to the blasting hose using clamp
bands every 1.5 m.
ATTENTION!
ALWAYS USE AN OIL-MOISTURE SEPARATOR WHEN USING REMOTE
CONTROL SYSTEM TO PREVENT WEAR ON RC VALVE.
BESIDES, AN OIL-MOISTURE SEPARATOR OPTIMIZES ABRASIVE BLASTING
OPERATIONS.
7.
Ensure that compressor is positioned out of the abrasive blasting operations zone on
downwind side.
8.
Start compressor and increase pressure and temperature up to operational values.
6