Too much ice on the evaporator
The
appliance
turns on,
Condenser blocked with dust
but the
temperature
Appliance is located near a heat source
is too high/
or air flow to the condenser is being
low
interrupted
Ambient temperature is too high
Unsuitable foodstuffs are being stored in
the appliance
Appliance is overloaded
Loose nut/screw
The
appliance is
unusually
The appliance has not been installed in
loud
a level or stable position
The
The set temperature is too low.
appliance
has difficulty
in reaching
and/or
Temperature probes broken or faulty.
maintaining
the set
temperature
There are refrigerant gas or fluid leaks
The condenser fins are covered with
dust.
Loss of cooling power caused by
frequent and/or prolonged opening of
the door.
The door gasket is not well sealed with
condensed water
Stop the machine and defrost
manually
Call your agent or qualified
technician
Move the refrigerator to a more
suitable location
Increase ventilation or move
appliance to a cooler position
Remove any excessive hot
foodstuffs or blockages to the
fan
Reduce the amount of food
stored in the appliance
Check and tighten all nuts and
screws
Check installation position and
change if necessary
Check that the parameters set
correspond to your temperature
requirements.
Check the integrity of the
temperature probe or replace the
probe
Identify the leak and close t (get a
specialist technician to perform
the check and repair).
Carefully remove dirt with a soft
bristle brush
check that the system works
properly.Check that there are no
obstructions in the air vents.
Remove dust from the gasket with
a hair dryer or use hot water at 45
° C