Herunterladen Inhalt Inhalt Diese Seite drucken

Product Features; Technical Data; Starting Operation - Bosch GAL 1830 W Originalbetriebsanleitung

Professional autoladegerät
Vorschau ausblenden Andere Handbücher für GAL 1830 W:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
 In case of damage and improper use of the battery, va-
pours may be emitted. Ventilate the area and seek
medical help in case of complaints. The vapours can irri-
tate the respiratory system.
 Do not place metal objects on the charger or between
battery and charger. Metal objects can heat up and lead
to injuries.
 Do not place credit cards or other magnetic data carri-
ers near the charger. Stored data on these data carriers
can be deleted.
Products sold in GB only: Your product is fitted with a
BS 1363/A approved electric plug with internal fuse (ASTA
approved to BS 1362).
If the plug is not suitable for your socket outlets, it should be
cut off and an appropriate plug fitted in its place by an author-
ised customer service agent. The replacement plug should
have the same fuse rating as the original plug.
The severed plug must be disposed of to avoid a possible
shock hazard and should never be inserted into a mains sock-
et elsewhere.
Intended Use
The charger is intended for recharging inductive Bosch Li-Ion
batteries (18 V). The inductive charging is performed by
means of a contactless charging process using magnetic in-
duction.

Product Features

The numbering of the product features refers to the illustra-
tion of the battery charger on the graphics page.
1 Inductive battery*
2 Standby indicator (green)
3 Charge status indicator
4 Error indicator (red)
5 Charging platform
*Accessories shown or described are not part of the standard de-
livery scope of the product. A complete overview of accessories
can be found in our accessories program.

Technical Data

Battery Charger
Article number
Output voltage (automatic volt-
age detection)
Charging current
Allowable charging temperature
range
Charging time for battery
capacity, approx.
– 2.0 Ah
– 5.0 Ah
Number of battery cells
Weight according to
EPTA-Procedure 01/2003
Protection class
Bosch Power Tools
GAL 1830 W
2 607 225 8..
V
18
A
3.0
°C
0 – 45
(80%)
100%
min
(35)
45
min
(65)
85
5 – 10
kg
0.6
/ II
Operation

Starting Operation

 Observe the mains voltage! The voltage of the power
supply must correspond with the data given on the name-
plate of the battery charger. Battery chargers marked with
230 V can also be operated with 220 V.
Charging Procedure
The charging process begins as soon as the mains plug of the
charger is plugged into the socket outlet and the inductive
battery 1 or the power tool with battery 1 (with base of the
battery) is placed onto the charging platform 5.
The charging process only begins when the battery capacity is
less than 85 – 90 %. This prolongs the life of the battery.
Due to the intelligent charging method, the charging condi-
tion of the battery is automatically detected and the battery is
charged with the optimum charging current, depending on
battery temperature and voltage.
This gives longer life to the battery and always leaves it fully
charged when kept in the charger for storage.
Meaning of the Indication Elements
Continuous Light Standby Indicator (green) 2
The continuous light of the green standby indica-
tor 2 shows that the mains plug has been plugged
into the socket outlet and the charger is ready for
use.
Flashing Charge Status Indicator 3
The fast charging process is indicated by
the flashing of the respective green LED of
the charge status indicator 3. When the re-
spective share of the battery is charged, the
green flashing light changes to a green continuous light.
The battery can be removed at any time and used. When all
five LEDs indicate a green continuous light, the battery is fully
charged.
Continuous Light Error Indicator (red) 4
The continuous light of the red error indicator 4
shows that the temperature of the battery is out-
side of the permitted charging temperature range,
see section "Technical Data". As soon as the per-
mitted temperature range is reached, the charger automati-
cally switches to fast charging.
Flashing Error Indicator (red) 4
The flashing light of the red error indicator 4 sig-
nals a different fault of the charger, see section
"Troubleshooting – Causes and Corrective Meas-
ures".
English | 7
1 609 92A 0HX | (3.7.14)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis