Herunterladen Diese Seite drucken

Technical Specifications - clage MBX 3 Lumino Montageanleitung

E-kleindurchlauferhitzer
Vorschau ausblenden Andere Handbücher für MBX 3 Lumino:

Werbung

MBX 3..7 Lumino

5. Technical specifications

Type
Art. No.
Capacity
Nominal pressure
Heating system
Required water resistance
at 15 °C in Ω cm
Electric supply
Nominal power rating
Nominal current
Temperature choice
Maximum inlet temperature
Factory flow setting at 3 bar
Maximum temperature incre-
ase at rated power and a flow
rate of...
1)
Required l/min to switch on
Required l/min to switch off
Min. required cable size
Weight filled with water
Dimensions (H × W × D)
Protection class acc. to VDE
Type of protection according to VDE
1) Temperature rise (Kelvin) + cold-water temperature =
maximum hot-water temperature (°C) ≤ 70 °C
2) The cable size must not exceed 4 mm
liter
MPa (bar)
2.0 l/min
2.5 l/min
3.0 l/min
3.5 l/min
4.0 l/min
l/min
l/min
mm
2)
2
2
MBX 3 Lumino
15113
0.2
1 (10)
bare resistance element / IES
≥ 1100
1/N/PE ~ 220 V – 240 V
3.5 kW
15 A
70 °C
2.0 l/min
25 K
20 K
17 K
14 K
12 K
1.2
1.0
1.5
approx. 1.5 kg
13.5 × 18.6 × 8.7 cm
10
MBX 7 Lumino
15117
0.2
1 (10)
®
system
≥ 1100
2/PE~ 400 V
6.5 kW
16 A
42 °C
70 °C
3.7 l/min
46 K
37 K
31 K
26 K
23 K
1.5
1.3
2.5
1
IP 25

Werbung

Kapitel

loading

Diese Anleitung auch für:

Mbx 7 lumino