When the function "Delayed Action Stop" has been activated, trig-
gering a new action will stop the execution of a delayed action whose
delay time has not yet expired .
off
function off (default setting)
on
function on
Volume adjustment
This value defines the initial volume when the power supply is switched
on .
0
dB, no attenuation (default setting)
−1 ... −127 attenuation 1 – 127 dB
Volume Min
This value has no significance for EPS110/ RS485 .
Level step
This value indicates the steps when adjusting the volume .
1 ... 100
dB per step
Level delay
Delay between steps when adjusting the volume .
0 ... 5000
ms
Level speed
Speed in dB/s when adjusting the volume .
0 ... 100
dB/s
Trackmode
The track mode is set here . When calling up a playlist, the play mode
is irrelevant .
folder All audio files (tracks) of a selected folder and the correspond-
ing subfolders will be played (default setting) . The files will
always be played in alphanumeric order .
track
Only a single track will be played .
Loopmode
off
Playing will stop at the end of the last track (default setting) .
on
Depending on the play mode selected, the current track (track
mode = track) or the current folder (track mode = folder) will
be repeated continuously . The files of a folder will always be
played in alphanumeric order .
Skipmode
The range for the skip commands NEXT and PREV is defined here .
This setting is irrelevant when calling up a playlist .
track
A skip command is used to skip to the beginning of the
current track and to play it again (default setting) .
folder The files from the current folder can be selected .
Skiploopmode
off
NEXT cannot be used to skip from the last track to the first
track, and PREV cannot be used to skip from the first track
to the last track (default setting) .
on
NEXT can be used to skip from the last track to the first track,
and PREV can be used to skip from the first track to the last
track .

5.1.5.2 Settings for the RS-485 interface

Baud rate (COM<n>_BR)
300 ... 256 000
Baud rate
The following values can be selected:
300, 600, 1200, 2400, 4800, 9600, 14 400, 19 200, 28 800, 38 400,
56 000, 57 600, 115 200, 128 000, 256 000 Bd
Number of data bits (COM<n>_DATA)
5 /6 / 7/ 8 number of data bits for a character
Number of stop bits (COM<n>_STOP)
1/ 1.5 / 2 number of stop bits for a character
Parity (COM<n>_PARITY)
none
even
odd
mark
(parity bit always 1)
space
(parity bit always 0)
Flow control (COM<n>_FLOW_CTRL)
none
hardware
hardware flow control with RTS/CTS (not for RS-485)
software
software flow control (XON / XOFF)
Receive Timeout (COM<n>_TIME_REC)
Receive timeout for a string . Reception of a string is terminated when
no further character has been received during the time defined .
0
no timeout (termination character required)
1 ... 60 000 time in ms
Sendpause after send (COM<n>_TIME_TRA)
Time between two strings .
0
no pause
1 ... 60 000 time in ms
Terminate string (COM<n>_TERMINATE)
Characters to terminate a string . It is possible to use 0 – 5 characters
for termination . If no character is used, a receive timeout must be set;
otherwise, reception of new strings will not be possible . The characters
are entered directly or as a character code .
The default setting for termination characters is "%0D%0A",
corresponding in hexadecimal to the usual control characters CR + LF
("Carriage Return" and "Line Feed") .

5.1.6 Saving a configuration file

Use the menu item "File
Save as ..." to save the configuration to
a desired location on the computer or SD card . If a configuration file
that has been saved is loaded again with "File
modified, it can also be saved again to the original location with
"File 
Save" .
To control EPS110/ RS485, the file saved must always have the
name "config .xml" and be in the root directory of the memory card .
Open ..." and then
19