Herunterladen Inhalt Inhalt Diese Seite drucken

Features; Operating Condition And Range; Introduction Of Different Modes - AquaForte MR. SILENCE MS280 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3. Features

DC Twin-rotary inverter compressor of Mitsubishi
a.
DC Brushless fan motor
b.
EEV Technology
c.
Quick reverse cycle defrosting with Saginomiya 4-way valve
d.
High-efficiency twisted titanium heat exchanger
e.
Sensitive and accurate temp control and water temp display
f.
High pressure and low pressure protection
g.
Full protection on electrical system
h.

4. Operating condition and range

To provide you comfort and pleasure, please set swimming pool water temperature efficiently and
economically.
a. Air temperature operating range: -10℃~43℃
b. Heating temperature setting range: 18℃~40℃
c. Cooling temperature setting range: 12℃~30℃
The heat pump will have ideal performance in the operation range Air 15℃~25℃

5. Introduction of different modes

The heat pump has two modes: Boost and Silence.
a.
They have different strengths under different conditions.
b.
Mode
Modes
Boost mode
Silence mode
5
Strength
Heating capacity: 20% to 100% capacity
Intelligent optimization
Fast heating
Heating capacity: 20% to 80% capacity
Sound level: 3dB (A) lower than Boost mode

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis