Horizontal Mounting - Bosch HI4000P Installationsanleitung

Infrarot-heizgerät
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
W
A (mm)
B (mm)
300W
340
360
500W
640
360
700W
940
360
850W
940
360
1000W
940
360
Table 15 Distances for the metallic panel (Fig. 3)
W
A (mm)
300W
340
500W
640
700W
940
850W
940
1000W
940
Table 16 Distances for the fixing frame for metallic panel
The screws should be suitable for the wall texture/material.
Do not, in any circumstance, install a panel with ceramic surface on the
ceiling!
Installation on the wall for ceramic panel
The ceramic version of the heater can only be installed on the wall.
▶ Use the installation frame included in the scope and mark four points
for the screws on the wall.
▶ Drill the holes and insert appropriate dowels.
▶ Using four flat-headed screws, fix the installation frame on the wall.
▶ Hang the panel on the installation frame.
▶ Use four nuts screwed on the bolts on the back of the panel to firmly
support the panel against the wall.
W
A (mm)
B (mm)
300W
340
360
500W
885
190
700W
660
360
Table 17 Distances for the ceramic panel (Fig. 3)
W
A (mm)
300W
340
500W
885
700W
660
Table 18 Distances for the fixing frame for the ceramic panel
In case of bathroom installation, observe the building installation
regulations according to IEC 60364-4-41. If necessary, the earthing can
also be established separately at the earthing protection provided for
this purpose on the back of the product.
The power supply must be protected by RCD switches and the product
must be earthed accordingly.
Infrared panels – 6721851963 (2023/01)
X (mm)
Y (mm)
592
592
892
592
1192
592
1192
800
1192
850
B (mm)
280
280
280
280
280
X (mm)
Y (mm)
592
592
1192
400
1192
592
B (mm)
280
115
280
WARNING
The metallic version does not have an additional earthing protection
device on the rear side.
Installing of the appliance
The panels are intended for vertical or horizontal installation. In case of
horizontal installation on the ceiling of a room, hang the panel on a
mounting frame. The minimum distance of the panel front wall and
lateral walls from inflammable objects is 10 cm.
Vertical mounting
▶ Mark the holes according to the tables in  Page 12.
▶ Drill out the holes, insert the dowels and drive the screw in to
protrude approx. 5 mm.
▶ Always fix the panel on two upper locks, two lower locks serve to a
reverse suspension of the panel.
▶ Connect the lead-in cable to a fixed power distribution in accordance
with the colour marking of the wires.
▶ Put the panel on the two upper locks.
See Fig. 9 at the end of the document.

Horizontal mounting

▶ Position the mounting frame in the location where the panel is to be
placed.
▶ Using a pen, mark the holes according to the holes on the frame.
▶ Drill the holes, insert the wall anchors and attach the mounting frame
with the screws.
▶ Connect the lead-in cable to the mains in accordance with the colour
of the conductors.
▶ Slide the panel into the mounting frame.
See Fig. 8 at the end of the document
Anchoring
It is forbidden to use wall anchors with a self-tapping thread to attach
panels to plasterboard/gypsum fibreboard ceilings.
Make sure to use the right type of anchoring element (wall plug),
particularly when dealing with plasterboard/gypsum fibreboard and
porous concrete structures.
When installing radiant panels on plasterboard or gypsum-fiber ceilings,
it is necessary to keep the distance between the panel and the ceiling of,
at least, 70 mm.
Uninstalling the panel from the wall
▶ Disconnect the panel from the mains using a two-pole switch before
uninstalling it.
▶ Lift the panel upwards vertically and sideways in such a way that it is
released from the screws.
▶ Disconnect the supply cable from the box on the wall.
Installation
13