Intended use

The infrared panel is intended for heating of living spaces.
▶ Comply with the connection conditions in accordance with the
specifications, standards and regulations of the relevant country.
▶ The appliance must only be set up or mounted outside the safety zone
(shown in grey  Fig. 7, page 74).
Any other purpose is considered improper use. Any damage that results
from such use is excluded from liability.
2.5

Product description

The Infrared panel is a wall mounted or ceiling mounted electric space
heating plate.
Ceiling mounting is only allowed to be performed by an expert.
Dimensions
The dimensions are shown in Fig. 4 at the end of the document.
Clearances
The clearances are shown at the end of the document and in page 12).
Regarding the vertical mounting (Fig. 5), the distance between the
bottom edge of the appliance and the floor must not be less than 50mm
(150mm is recommended). The clearance distance on the side must be
at least 50 mm and 50mm is the minimum in the upward direction. There
must be at least 50 cm of free space in front of the panel.
W
h (m)
300W
2,5
500W
2,5
700W
≥2,7
850W
3
1000W
3
Table 12 Distances for ceiling mounting (Fig. 6)
2.6

Product identification

Data plate
The data plate contains performance data, approval data and the serial
number of the product.
The data plate can be found on the backside of the product.
3
Commissioning
If the appliance is installed or set up in or was previously stored in a much
colder environment, it must be allowed to adjust to the room
temperature.
▶ Wait half an hour before switching on the appliance.
When the appliance is heating for the first time, it may emit a slightly
unpleasant odour (for 2 hours at the most) which is caused by the
product residues drying out.
12
4
4.1
Surface temperature
The maximum surface temperature of the appliance is up to 110 °C.
Therefore no special safety measures are required to protect flammable
materials and fitted furniture. Country-specific regulations must be
observed.
Wall structure
The wall used for installation of the appliance must be load-bearing and
the appliance must be able to rest on it over the entire surface.
Protection zones in damp areas
Observe the clearances for damp areas in Fig. 5 at the end of the
document.
Observe all the current applicable national and regional regulations as
well as all technical rules and guidelines. These may contain additional or
deviating requirements for installations in damp areas.
▶ Do not install any switches, sockets or devices with mains power
▶ Connect device to a residual current circuit breaker.
▶ Use only control units with suitable IP rating.
x (m)
0,6
5
0,6
Installation on the wall/ceiling for glass and metallic panel
1,2
The glass and metallic version of the heater can be installed on the wall
≥1,2
or on the ceiling. Note that, only the glass version of up to 800W can be
≥1,2
installed in the ceiling.
▶ Use the installation frame included in the scope and mark four points
▶ Drill the holes and insert appropriate dowels.
▶ Using four flat-headed screws, fix the installation frame on the wall/
▶ Hang the panel on the installation frame.
▶ Use four nuts screwed on the bolts on the back of the panel to firmly
Mark six points for the screws on the glass panel of 850W, as seen in
Fig. 4 at the end of the document. Use the fixing frame with six points for
ceiling mounting.
W
300W
500W
700W
850W
Table 13 Distances for the glass panel (Fig. 3 up to 700W, Fig. 4 for the
W
300W
500W
700W
850W
Table 14 Distances for the fixing frame for glass panel

Preconditions for installation

Installation location requirements

supply in the protection zones.

Installation

for the screws on the wall/ceiling.
ceiling.
support the panel against the wall/ceiling.
A (mm)
585
1200
1185
1185
850W version)
A (mm)
340
885
660
383/766
Infrared panels – 6721851963 (2023/01)
B (mm)
585
400
585
785
B (mm)
280
115
280
280