Herunterladen Inhalt Inhalt Diese Seite drucken

Nordcap VAR-PH14 Bedienungsanweisung Seite 15

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ENGLISH
5.2 DEFROST PARAMETER SETTING
To change the automatic defrost settings you need to adjust the following parameters of the thermoregulator:
Defrost interval (hours)
Defrosting cycle time (minutes)
Procedure:
1. Press simultaneously the keys
2. Press the key
until the display shows
Press
.
Press the key
or
Press again
in order to confirm.
3. Press the key
until the display shows
Press
.
Press the key
or
Press again
in order to confirm.
4. After about 15 seconds the thermoregulator will automatically exit the set function and display the temperature again.
The refrigerated unit for chocolate always works with ventilated refrigeration and the controller does not have the keys
and
which are not needed.
The inside humidity is always less than 45% thanks to the conformation of the aluminum panels covering the serpentine.
The moisture level cannot be set and is only viewable with a special controller OPT-TVU (optional).
The temperature controllers of all the showcases are blocked so that the user cannot set lower temperatures than those planned
PARETE VINO +3 ° C (excluding PHCAR10-20 +12 ° C) TECA +4 °C (excluding TH-C10-20 +12 °C). It is not allowed to enter the
hidden parameters and modify these values. The showcases are not designed and built to operate at low temperatures. Failure
to comply with this provision will invalidate the warranty.
If the display shows the warning light
condenser has exceeded the safety limits set by the manufacturer. The reasons may be as follows:
• The space at the bottom of the unit (8 cm) was blocked, preventing the air exchange.
• The ambient temperature and humidity are too high.
• The condenser is completely blocked with dust, compromising the ventilation.
Clean it as indicated in section 4.1.
5.3 HEATED FRAME AND RAIL
An heating element is installed on all the showcases (Parete -> Frame ) (Teca -> Rail) which can be activated with the
AUX key on the thermo-regulator (excluding models with
This technical device solves the problem of condensation on the metal parts due to the difference of temperature
between the inside of the showcase and the ambient temperature, especially in places with very high temperature and
humidity.
It is very important to use this feature in tropical countries and marine locations because even a small presence of
condense for long periods may damage the external decorative coating of the showcase.
In locations with continental climate with normal temperature and humidity conditions it is not necessary to use this
device. The same goes for the showcase set at the storage temperature (+14 +16 °C).
and
until the display shows
.
and set the desired value.
.
and set the desired value.
P*CAR10 / P*CAR20 / P*CDR20 / TC10 / TC20
MINIMUM ADJUSTABLE TEMPERATURE
CONDENSER TEMPERATURE ALARM
it shows that the temperature detected by the second probe placed on the
.
)
15
+4 / +16 °C
SET 14 °C
TA 30°C

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

446214002

Inhaltsverzeichnis