5. Place the adapter wires on the cable holder dividers
6. Place the devices in the dividers
All manuals and user guides at all-guides.com
Charging System
Charging 30 to 40 devices at one time can overload a typical 15 amp circuit. V7 Charge Carts are equipped with a built-in timing device that automatically switches the AC power supply from
one half of the device outlets to the other, at specified intervals to help protect against overload. 
 
The timer module will provide power to each set of 15 (for 30 device cart) or 20 (for 40 device cart) outlets for the amount of time indicated on the timer (default is set to 15 minutes).
When that time expires, the cart will change power to the other set, and continue to alternate sides. Every time power is turned off and then restored to the cart, power starts with the first
set.
 
The LED indicator on the outside of the cart will show you which set is currently charging.
 
The timer is factory-set on a 15-minute cycle. Devices with fully depleted batteries will require more than one cycle to fully charge.
 
Circuit Breaker:
 
There is a circuit breaker on the cart. If there is no power to internal and external outlets, check to see if the circuit breaker is tripped.
 
Adjusting the Timer (Optional for advanced users):
 
Adjust the timer to the amount of minutes you want it to cycle. The 15 minute cycle should be optimum for most applications and we don't recommend adjustment. If adjustment is
required, it should be done by a qualified technician. The timer range is from 15 to 240 minutes. You can also set it to the ON position which will make all the outlets on.
Note: be careful not to overload the circuit.
 