INSTALLATION

General

EN 10
This appliance should be connected to the mains power by a registered
installer, who knows and applies the correct safety specifications.
The appliance meets European requirements.
Important information:
• The distance between the lowest point of the cooker hood and
the gas hob should be at least 65 cm. With an electric, ceramic or
induction hob this distance should be at least be 55 cm.
• If the appliance is connected to an existing outlet channel, no other
appliances should be connected to that channel (such as a water
heater or boiler).
• Follow the applicable local regulations regarding the ventilation of
gas appliances.
• With a short exhaust-air pipe and few bends, the cooker hood will
work better.
• Prior to drilling check that there are no pipes or cables present.
• The cooker hood connection pipe is 125 mm in diameter. It is best
to use this diameter for the exhaust-air pipe.
• The installation material provided with this cooker hood is suitable
for reinforced concrete and brick walls. You will need special plugs
and screws for certain walls.