5 POSSIBLE ERRORS

Switch ON time
Switch ON time programmed
No setting
Day block (e.g. 1, 2, 3, 4, 5)
Day block
Switch ON time programmed
(e.g. Wednesday, 9 00)
ON and OFF switch times occur at the same time (e.g. Wednesday, 9 00)
table 06
Possible errors

4.2.5 Skip-Function (Soft-Override)

The Skip Function changes the switching mode of the time
clock connected until the next step of programme is reached.
For instance: if the appliance is in ON mode, pressing the
Skip-button '-X->'will immediately turn it off and vice-versa.
Proceed as follows:
• Set the right sliding switch to position RUN.
• Pressing Skip button „-X->" once switches Channel 1 (CH).
• Pressing Skip button „-X->" twice switches Channel 2
(DHW).
• The time clock will change over to the opposite switching
mode.
• The Skip symbol (-X->) show up in the Display..
• Further pressing of the Skip button „-X->" brings up the Skip
Function again.
• In the Skip Function the display of the number and the
symbol occurs after a lapse of about 3 seconds.
• The Skip Function only operates until the next programmed
switch time is reached. At this point the Skip Function is
deleted and the programmed switch time cycles are
activated again.
Every switch ON point is closely linked to the following
switch OFF point. Therefore the following combinations
of on/off switching can, for example, lead to errors:
Switch OFF time
No setting
Switch OFF time programmed
Different day block (e.g. 1, 2, 3, 4, 5, 6)
Week day
Switch OFF time is before the switch ON time on the same day
(e.g. Wednesday, 8 59)