  • Seite 1 SolarLake 5500TL-PM SolarLake 7000TL-PM SolarLake 8500TL-PM SolarLake 10000TL-PM...
  • Seite 2 Samil Power Software www.SAMILPOWER.com...
  • Seite 3: Inhaltsverzeichnis

    Table of Contents About this Installation Guide ..2 Mounting the Inverter....13 Safety Symbols....... 3 AC- and DC-Connection ....16 General Safety Requirements ..4 Starting the Inverter ...... 20 Intended Use ........5 Commissioning ......21 Inverter Configuration ....24 Inverter Function......
  • Seite 4: About This Installation Guide

    Max. DC-Power 5750 W Qualified technicians Supplier Company the product Max. AC-Power 5500 W Manufacturer: was purchased from Samil Power Co. Ltd. Inverter SolarLake PV-inverter No.6 Xuefengshan Road, described in this Suyu District, Suqian, installation guide Jiangsu Province, 214174 P.R.C SolarLake 7000TL-PM Über diese Installationsanleitung...
  • Seite 5: Safety Symbols

    Safety Symbols Life threatening voltages are Countermeasures that must processed inside the inverter. be taken in order to avoid the Hazardous situations that can lead to hazardous situation are indicated with death or serious injuries are indicated an arrow: Î “This is an example how to avoid a with the “WARNING”...
  • Seite 6: General Safety Requirements

    General Safety Requirements 1. WARNING! Danger of electric shock! 4. 2 people are required for Î Read Installation Guide lifting and transporting. carefully. Follow all WARNING! Danger of electric shock and fire! instructions. Î Never modify the inverter unless 2. Contact your supplier when you have questions.
  • Seite 7: Intended Use

    Intended Use The inverter (1) converts DC-power CAUTION! Risk of damaging from the PV-generator (2) to AC- the inverter! Î Do not connect other DC-power power. The AC-power is fed into the grid (3). In case of a grid failure: The sources (6) such as wind power inverter automatically disconnects systems, hydroelectric generators,...
  • Seite 8: Inverter Function

    Inverter Function 1. DC-side surge voltage protection 8. Digital output port 2. DC-side insulation monitoring 9. Digital input port 10. Goldfinger communication 3. DC-side disconnection switch (optional) extension port 4. Display, status LEDs, buttons 11. Residual Current Device (RCD) 5. AC-side disconnection relay 6.
  • Seite 9: Labels And Markings On The Inverter

    Labels and Markings on the Inverter Symbols on Type Label: Markings and Symbols on General Symbols bottom of Inverter: 1. Ensure proper disposal 7. AC-plug 2. CE-mark 8. Opening for relay connection Safety Symbols 9. Ethernet connection 3. Read documentation! 10.
  • Seite 10: Connections On The Inverter

    Connections on the Inverter 1. DC-switch (optional) 2. DC-plugs 3. Ethernet connector 4. Cable gland for digital input and digital output 5. Valve for pressure discharge 6. AC-plug 7. Optional goldfinger communication port Verbindungen am Wechselrichter 1. DC-Schalter (optional) 2. DC-Stecker 3.
  • Seite 11: User Interface

    User Interface 1. Green LED: 4. OK-Key On = Normal operation, Press OK-key in order to confirm entry. Flashing = Waiting, checking or starting up, Off = Possible failure 5. Cursor-Keys: 2. Red LED Pressing the cursor keys On = Failure, navigates the menu and increases Flashing = Temporary failure, or decreases values.
  • Seite 12: Warranty And Guarantee

    To whom it may concern, For the information on our warranty terms and conditions, please see our website: www.samilpower.com. Samil Power Co., Ltd. a company incorporate in P.R. China (registered number 321300000037964) having its Garantie légale et commerciale Fields marked with ☆ are required information.
  • Seite 13: Unpacking

    Unpacking Proceed as follows: Packing List: • Check the packaging for 1. Inverter damages. 2. Wall mounting bracket • Unpack the inverter and check 3. DC-plugs (4 sets) if all items of the packing list are 4. AC-plug included. 5. Installation guide •...
  • Seite 14: Required Tools

    Required Tools The following tools are required for 7. Screwdriver the installation of the inverter: 8. Hammer 1. Crimping tool for DC-plugs 9. Level (e.g. type PV-CZM) 2. Cable stripping tool for DC-cables (e.g. PV-AZM) 3. Drill 4. Multimeter 5. Open-end spanner kit for DC- plugs (e.g.
  • Seite 15: Mounting The Inverter

    Mounting the Inverter Requirements for the installation 4. Check correct position. location are specified on the following 5. Optional: Secure the pages. inverter with a padlock. Proceed as follows: 1. On plasterboard walls: Use center holes. Screw wall mounting bracket to wall stud. 2.
  • Seite 16 SR50-10TL-PM-IG_10_ENDEFR0514...
  • Seite 17 SR50-10TL-PM-IG_10_ENDEFR0514...
  • Seite 18: Ac-Anschluss - Voraussetzungen

    AC-Connection - Requirements 1. Use 25 A circuit breaker. 4. Recommendation: Keep 2. A Residual Current Device cable losses below 1 %. (RCD) is not required. In case Keep impedance below 2 Ohm. an RCD is mandatory: Use an 5. The maximum outer diameter of RCD >...
  • Seite 19 Assembly of the AC-Plug WARNING! Risk of electric shock! 5. Remove swivel nut and Î Deactivate AC-voltage when shove swivel nut over connecting the AC-connection cable. plug. 6. Attach wires to AC-plug. Proceed as follows: 7. Tighten swivel nut. 1. Disconnect voltage. 8.
  • Seite 20: Dc-Anschluss - Voraussetzungen

    DC-Connection - Requirements 1. CAUTION! Risk of damaging the 4. The DC-ports can be inverter! connected: Install diodes Î Ensure that the voltage and in order to avoid reverse currents. current is below the specified 5. Cover PV-modules when working values.
  • Seite 21: Montage Der Dc-Stecker

    Assembly of the DC-Plugs WARNING! Risk of electric shock! 5. Insert plug contact in plug. Î Cover PV-modules when working Pull on contact in order to on the connection cables. check that the contact is locked in Proceed as follows: the plug.
  • Seite 22: Starting The Inverter

    Starting the Inverter Proceed as follows: In case you are starting the inverter for the first time: 1. Connect AC-plug. 2. Connect DC-plugs. The inverter needs to be 3. If present: Turn DC-switch on. commissioned. Commissioning is 4. Turn AC-fuse on. described in English on page 21.
  • Seite 23: Commissioning

    Commissioning • After connecting to AC and DC Specify Date and Time. Date/Time - - - • Press OK to confirm. power the inverter presents the screen on the left. SamilPower Co., LTD. • YYYY Press OK to start 2 0 1 4 commissioning.
  • Seite 24: Inbetriebnahme

    Inbetriebnahme • Nach Anschluss der AC und Geben Sie Datum und Uhrzeit Datum/Uhrzeit - - - DC Seite präsentiert der ein. • Wechselrichter das Fenster links. Drücken Sie OK um zu SamilPower Co., LTD. • YYYY Drücken sie OK um die bestätigen.
  • Seite 25: Mise En Service

    Mise en service • Une fois les côtés AC et DC Entrez la date et l'heure. Date / heure - - - connectés, l'onduleur affiche la • Appuyez sur OK pour confirmer. fenêtre de gauche. SamilPower Co., LTD. • Appuyez sur OK afin de AAAA 2 0 1 4 démarrer la mise en service.
  • Seite 26: Inverter Configuration

    Additional Inverter Configuration Use the SamilPower SolarPower SolarPower Browser can be Browser for configuration. used for various settings: In general the inverters are connected to a PC (3) with ethernet (1). A router SolarPower Browser is available for (2) can be used in order to connect download at: several inverters.
  • Seite 27: Opening The Inverter

    Opening the Inverter Proceed as follows: 4. WARNING! Danger of 1. Ensure that no water will enter electric shock! Î Wait for 5 minutes in order to when the inverter is open. 2. Disconnect AC-power: Remove let internal voltages discharge AC-plug.
  • Seite 28: Accessories

    Accessories The inverter can be equipped with 2. RS485 interface, additional communication interfaces. Ordering No. 910-74010-00, e.g. 1. Wifi interface, Ordering No. 910- for connection of one or several 74009-00, e.g. for connection of inverters to a data-logger one or several inverters to a PC or router Information: The inverter can only be equipped with one type of...
  • Seite 29: Sd Card / Digital Input / Digital Output

    SD Card / Digital Input / Digital Output The inverter is equipped with the Schematic diagrams of following interfaces: examples for connecting the 1. SD-card memory port: For digital ports are available on the extension of the inverter memory following pages. and storage of yield data.
  • Seite 30: Digitale Eingänge

    Digital Input Ports The inverter is equipped with 4 digital input ports (1). The digital input ports can be used for the connection of a ripple control receiver (2). Digitale Eingänge Der Wechselrichter ist mit 4 digitalen Eingängen ausgestattet (1). Die digitalen Eingänge können für den Anschluss eines Rundsteuer- signalempfängers (2) benutzt...
  • Seite 31: Digital Output

    Digital Output The inverter is equipped with 3 digital output ports (relay) (1). The usage is possible with future firmware versions. Check www.SAMILPOWER.com for details. Digitaler Ausgang Der Wechselrichter ist mit 3 digitalen Ausgängen (Relais) (1) ausgerüstet. Diese können mit späteren Firmwareversionen benutzt werden.
  • Seite 32: Technical Data

    Power / Nominal Power Output Power / Nominal Power Technical Data SolarLake SolarLake SolarLake SolarLake 5500TL-PM 7000TL-PM 8500TL-PM 10000TL-PM Input (DC) Max. DC power (@cosφ=1) 5750 W 7400 W 8900 W 10350 W Max. input voltage 1000 V MPP voltage range / rated input voltage 250 V - 800 V / 620 V 320 V - 800 V / 620 V 390 V - 800 V / 620 V...
  • Seite 33: Technische Daten

    Leistung / Nennleistung Output Power / Nominal Power Technische Daten SolarLake SolarLake SolarLake SolarLake 5500TL-PM 7000TL-PM 8500TL-PM 10000TL-PM Eingang (DC) Max. DC-Leistung (@cosφ=1) 8900 W 5750 W 7400 W 10350 W Max. Eingangsspannung 1000 V 390 V - 800 V / 620 V MPP Spannungsbereich / Nennspannung 250 V - 800 V / 620 V 320 V - 800 V / 620 V...
  • Seite 34: Données Techniques

    Puissance / Puissance Nominale Output Power / Nominal Power Données Techniques SolarLake SolarLake SolarLake SolarLake 5500TL-PM 7000TL-PM 8500TL-PM 10000TL-PM Entrée (DC) Puissance DC maximale (@cosφ=1) 5750 W 7400 W 8900 W 10350 W Tension d’entrée maximale 1000 V Plage de tension / tension nominale MPP 250 V - 800 V / 620 V 320 V - 800 V / 620 V 390 V - 800 V / 620 V...
  • Seite 35 One-Stop Shopping Samil Power Product Portfolio SolarPond SolarRiver 240 W 1.0 - 5.75 kW SolarLake Accessories 5.5 - 30 kW SolarWatcher 500 SolarWatcher 100 Array Combiner Boxes SR50-10TL-PM-IG_10_ENDEFR0514...
  • Seite 36 www.SAMILPOWER.com...

Inhaltsverzeichnis