OPERATION

COOLING

G
Place the air conditioner as near as possible to the window. Fit the flexible tube by hooking
it to the rear of the unit. Extend the flexible tube just enough to reach the outdoor, passing
under the window shutters set ajar.
G
In case there is a window sill towards the inside of the room, it might be better to use the
supplied outlet nozzle. Insert the nozzle into the free end of the flexible tube.
G
Open the window and lock one of the shutters. Place the outlet nozzle between the two
shutters.
G
Avoid sharp bends or plies of the flexible tube.
G
In case of porthole utilise make a 140 mm diameter hole in the window pane.
Turn the knob (D) of the thermostat in clockwise direction until you reach the position
G
of maximum cooling.
G
Switch on the air conditioner pressing the ON/OFF push-button (A)
ations are displayed.
G
Select the cooling operation pressing the push-button (B)
G
Press the push-button (C) to select the high fan speed, lamp (F) lights.
NOTE
The air conditioner disposes of the condensate water automatically at the HIGH fan
speed, on the contrary at the LOW fan speed the condensate water is collected in
the tank.
G
Now slowly twist the thermostat knob back towards the left until the compressor stops.
At this point the air conditioner is set for automatic operation under the control of the electronic thermostat to maintain the room tempera-
ture at the pre-set value.
G
To stop the air conditioner press again the ON/OFF push-button. (A).

DEHUMIDIFICATION (DRY)

When the air conditioner is in the dehumidification mode, it doesn't cool the room.
When you use the air conditioner in the dehumidification mode, you don't have to
use the flexible tube. For maximum dehumidification efficiency leave the rear dis-
charge outlet free to discharge directly into the room.
G
Remove the flexible tube by grasping it at the attachment point on the air condi-
tioner and twisting it until you release it from the blocking hooks.
Press the ON /OFF push button (A)
G
Select dehumidification mode pressing the push button (B)
up. The humidity of the room (condensate water) will be collected in the internal
tank of the air conditioner.
G
To stop the air conditioner press again the ON/OFF push-button. (A).
WARNING !
The air conditioner may be used as dehumidifier only if the room temperature is
above 10 °C. When the room temperature is below 10 °C, the compressor stops and
the dehumidification doesn't occur, while the fan goes on working.
ATTENTION:
the control causes a compressor starting delay of about three minutes each
time buttons A, B and thermostat D are activated or when the plug of supply
electric cable is took out and in.
All manuals and user guides at all-guides.com
, lamp (E) lights.
I
A
to start the air conditioner.
,lamps of last oper-
D
C
B
, lamp (H) lights
EG
NO!
H
E
F
G
4

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis