Auto Lock
With this function, you can lock the buttons of the Control Board to e.g. prevent menu tampering. If this
function is activated, the buttons will be automatically locked in 15 seconds from the last command. In order
to deactivate or temporarily deactivate the key lock function, enter the password (see table Menu structure)
Op.Time
With this function, you can display the running time of the device. The display shows "XXX", "X" stands for
the number of hours.
DFSE
With this function, you can reset the device to the default setting. Set DFSE to ON.
RDM
With this function you can call up various parameters via RDM.
This device is RDM ready. RDM stands for "Remote Device Management" and makes remote control of
devices connected to the DMX-bus possible. ANSI E1.20-2006 by ESTA specifies the RDM standard as an
extension of the DMX512 protocol.
Manual settings like adjusting the DMX starting address are no longer needed. This is especially useful when
the device is installed in a remote area.
RDM is integrated in the DMX-protocol without influencing the connections. New DMX-cables are not
necessary. RDM ready and conventional DMX devices can be operated in one DMX line. The RDM protocol
sends own packages in the DMX512 data feed and does not influence conventional devices.
If DMX splitters are used and RDM control is to be used, these splitters must support RDM.
The number and type of RDM parameters depend on the (optional) RDM controller being used.
In order to see or to change the RDM PID code if required, press the MODE button and choose FIXTURE ID.
Press the ENTER button.
Enter the password 050 via the UP or DOWN button.
You can now see or, if necessary, change the individual RDM PID code of the fixture via the UP or DOWN
button.
Please press the ENTER button to confirm and the MODE button to exit the Mode.