ENGLISH: Chameleon
Sirius X
®
INSTRUCTIONS FOR USE AND MAINTENANCE * PLEASE SWITCH OFF MACHINE BEFORE SERVICING
Replacement of the cover is the opposite procedure of removal.
It may also be beneficial to rotate the cover when mounting the unit in the vertical orientation, if for example the unit
is being located near to the corner of a room, which would otherwise limit access when replacing the glue board.
INSTRUCTIONS FOR HARDWIRING THE UNIT
The unit also has the option of being wired through a knockout in the rear panel to allow connection directly into
the buildings fixed wall light wiring. A knockout is provided for this on the rear panel and a terminal block can be
found inside the enclosure for the electrical connections. If this option is used it should be performed by a qualified
electrician and the existing power cord should be removed from the product and discarded. Ensure the unit is
properly earthed.
CAUTION - Ensure the mains power supply is switched off at the fuse box and remove the fuse or circuit
breaker protecting the circuit.
Firstly, the unit must be disassembled by removing both the front cover and reflector components.
Unscrew the 4 screws which are securing the cover to the mount panel using a pozidrive screwdriver, the cover can
now be removed. Place the cover front side down on a soft, debris free surface to avoid any scratching of the cover.
Remove the two LED lamps and place to one side.
Next, unscrew the 4 remaining screws securing the reflector.
The reflector can then be moved to gain access to the internal wiring.
Unscrew the small screws on the connector block which are holding in place the live, neutral and earth wires leading
from the power cord and pull them out of the connector block. The power cord can now be removed from the unit by
compressing the strain relief bush. This cord should now be discarded.
The knockout panel should then be removed by wedging a flat head screwdriver into the knockout slit and tapping
the screwdriver with a hammer gently. Excessive force may deform the mount panel. Once the edge of the knockout is
bent, you can then grip the corner with pliers and twist until the securing tabs break loose. If the edges of the hole are
sharp, they should be gently filed down to ensure no wires can be cut or damaged when passing through.