7. Placement of the Dirt Water Pump

• Attach a sufficiently strong, water-tight rope to the carry handle to lower the dirt water pump, e.g. into a well.
The dirt water pump must never be held or attached by the mains cable! This may damage the mains cable;
there is danger to life from electric shock! The dirt water pump also must not be attached via the hose.
Fasten the rope to a suitable holder.
• To connect the hose used by you to the dirt water pump, you may use the enclosed L-shaped pipe piece and the
hose connection.
Observe that the diameter of the hose used and the required connections are designed accordingly.

8. Commissioning

• The pusher at the dirt water pump can be used to choose between automatic („AUTOMATIC") and manual mode
(„MANUAL").
In automatic mode, the dirt-water pump is controlled by an internal float switch. When the water level drops, the dirt
water pump is switched off. When the water level rises, it is switched on again.
In the manual operating mode, the dirt water pump is always activated, independently of the float switch. The dirt
water pump pressure pump must not be operated unsupervised then, because the dirt water pump will not switch
off if there is no water, which would damage the pump (running dry).
• After lowering the dirt water pump into the well, etc. by a rope and fastening the rope accordingly, plug the mains
plug into a properly installed protective ground mains socket. This must be an IP44 mains socket for operation in
the outdoor area.
The mains plug must only be plugged into the mains socket when dry. There is danger to life from electric
shock otherwise!
• If no water is conveyed, there is still air in the dirt water pump and the hose (or the water level is too low). You may
be able to accelerate the intake process if you fill water into the hose or move the dirt water pump slightly back and
forth or plug the mains plug in/out.