Herunterladen Inhalt Inhalt Diese Seite drucken

Functions - Termat MTPCR500T Installationsanleitung Und Gebrauchsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 25
EN
INSTALLATION AND USER MANUAL
Make sure that the mains voltage is the same as indicated in the
When installing in a room with a bath or shower, respect the "protec-
security directives.
For models that do not have a plug, it is necessary to install a suita-
ble omnipolar switch to ensure complete disconnection if necessary.
WARNING! Do not rotate the device.
Do not cover the equipment control with any towel.
Connect the energy cable.
tion yourself so that the control is out of this space. Under no circumstances can it be placed within
volume 1.
Place the electric towel rail against the wall in the desired position.
Using a pencil, mark your position on the wall around the support tubes. Make sure there is no
wiring in the wall where you are going to drill.
With the help of a suitable drill and drill, drill the holes in the tile / wall to the required depth.
Important: the holes must be drilled correctly aligned and appropriate to the diameter of the
block and the length of the wall anchor bolts.
support of the electric towel rail.
the brackets with the anchor bolts.
Voltage supply
IP grade
Selectable power range
Conformity marking
Operating temperature
F. Functions
6 modes: Comfort, Night, Frost, Chrono, Timer-2h and Stand-by.
"Comfort" mode: the electronic control maintains the temperature at the value selected by the
user for this mode.
"Night" mode: the electronic control keeps the temperature at a lower value than the "Comfort"
temperature selected for this mode.
"Frost" mode: the electronic control maintains the ambient temperature above 7°C.
"Timer 2h" mode: the electronic control keeps the heating element on for a period of 2 hours
regardless of the set temperature. At the end of the 2 hour period the device returns to the
previous operating mode. For safety reasons, during the two hours of this period of time, the
"Chrono" mode: the electronic control works according to a daily / weekly program. The pro-
230VAC - 50Hz
IP44
7ºC ÷ 32ºC
CE
-10ºC ÷ +40ºC