STARTING THE UNIT:

The generator should not run at maximum load for more than 15 minutes. For continuous operation, do not exceed the rated power. In
each case, consider the total load of all connected loads.
If the starter-equipped generator does not start within 5 seconds, wait approximately 15 seconds before trying again.
Do not draw current from any of the generator's outlets in excess of the limit specified for a single outlet.
Do not connect the generator to the building network. This may damage the generator or household electrical appliances.
Such a connection may only be made by a person with appropriate authorizations.
Do not run the generator near other power lines/conductors such as overhead power lines.
Significant overloads can damage the generator, small ones can shorten its life.
Make sure all loads are in good working order before powering up from the generator. Should any start to operate abnormally (scuffing
or stopping unexpectedly), shut down the generator immediately, disconnect the device, and diagnose it.
• The ignition key can be placed in three positions. • The key
switch is used to start and stop the engine.
"OFF" position - to stop the engine
"ON" position - to operate the generator after starting the engine
"START" position - to start the engine
• Turn the ignition key to the "ON" position (ignition on), then turn it to the "START" position and release it after
starting the engine.
Switching on and off the voltage to the sockets and output terminals of the generator is possible by means of the main switch on the
control panel after moving the switch lever to the "ON" position
The main switch will automatically trip when a short circuit or overload is detected in the electrical circuit while the generator is running.
Before switching the circuit breaker back on, check and remove the cause.
The generator voltage can be switched on to the receivers only after the engine speed has stabilized.

STOPPING THE ENGINE:

To stop the engine:
Disconnect the receivers
Let the engine run for 5 minutes, then turn it off
(turn the ignition switch to the "OFF" position) and
close the fuel valve.
During start-up, most electric motors draw much more current than their nominal
operating current
Keep the electrolyte level in the battery between high and low. Do not overfill!
The generator is not equipped with thermal generator protection and overheating
of the current system may occur.
The internal combustion engine must not be turned off while the generator is
running under load.