To ensure that the fan operates normally, it is necessary to control its minimum speed of rotation.
Proceed as follows:
turn the control knob in the counter-clockwise direction to the extreme position without switching the controller off
switch on power supply
turn the potentiometer screw by means of an insulated screwdriver (see PIC. 2) until the speed of rotation is
minimal
turn the control knob to the off position (in the counter-clockwise direction until it "clicks"), wait until the fan stops
switch the controller to the minimal speed again, the speed of rotation is set to the minimum.
CAUTION!
It is prohibited to control the fan by means of the controller if the minimum speed is not set correctly! Damage to the fan
may result.
Fix the controller cover and secure it with a nut.
Replace the control knob.
The controller should start working immediately after being connected to the source of voltage.
If the unit does not start working at once, check it for possible problems according to the table.
Fault
The unit is not working.
The controller is on, the fan is not
working.
The product must be transported and stored in the original packaging in a dry, well-ventilated environment at
temperatures from +5 °C to +40 °C and a maximum relative humidity of 80% (at a temperature of +25 °C).
After assembly

Possible faults and their elimination

Possible cause
No or limited connection.
Ruptured fuse.
The minimum rotation speed has
not been set correctly.

Storage conditions

20
Elimination
Check the correct connection to
power supply.
(see Assembly)
Replace the fuse.
Reset the minimum rotation speed.