1.2 Operation

The time and the level of storage heater charging can be changed or set during normal operation.
Changing/setting time . . .
Button
LCD
P
09 : 16
09 : 16
Press
Ändern der Wärmespeicher-Aufladung . . .
Button
LCD
+/-
P
Press
twice
Power failure
The clock has a power reserve of approx. 6 hours in the event of a power failure. The set
parameters (e.g. charging model) are stored permanently.
If the power failure lasts longer than approx. 6 hours, the clock will be set to 00:00 again and flash
until the time is changed (see above).
Summer/winter time
Deviations of approx. 1 hour between the displayed time and the actual time have no effect on the
functions of the ELFAMATIC µC 3000.

1.3 Troubleshooting . . .

"FU" (open circuit in sensor) or "FS"
(short-circuit in sensor) and the time are
displayed alternately.

1.4 Putting into operation

1. Basic settings
The charging model and atmospheric sensor are specified in the respective list.
Changes to the individual parameters are adopted immediately after they are entered. If no button
is pressed for 15 minutes after a change has been made (irrespective of which parameter has been
changed), the display automatically returns to the default display (time and outside temperature
are shown alternately).
Button
VR LF LZ KU
Press
+
or
ED
SH
SYN
Button
VR LF LZ KU
Press
+
or
ED
00
SH
,
SYN
For the User and the Fitter
Button
Note
Holding down the button activates rapid
P
setting mode.
If no button is pressed for 15 minutes, the
set time is adopted automatically and the
Press
backlight switches off.
twice
Button
Note
P
In this menu, the basic charging mode of all
storage heaters connected to the ELFAMATIC
µC 3000 can be changed by +/–4 °C
according to requirement. 1 °C corresponds
Press
to approx. 3.5 % more/less charging
(max. +/–15 %).
The charging rate should be changed in
small steps only (0.5–1 °C) as any change
does not become noticeable until the
following day.
The atmospheric sensor and/or the selected
setting for the atmospheric sensor must be
checked by a specialist technician.
23