1. The illuminant has to be replaced by a qualified professional only
--- m = 0,45 m

5. Trouble shooting

POSSIBLE CAUSE

➢ The plug of the appliance is not
connected to the socket.
➢ The plug has become loose.
➢ The socket is not supplied with
energy.
➢ The fuse is switched off.
➢ ventilation damper blocked.
➢ motor mounting defective.
➢ motor defective
➢ one-way valve is leaky
➢ connection base chimney-telescopic
chimney is leaky
➢ motor not properly fixed
➢ hood not properly fixed
➢ too much distance hood-hob
➢ too much draught because of open
doors and/or windows
8
Not included in guarantee.
Required minimum distance to surfaces such as pot lids, oven
cloths etc. to avoid any hot parts and risk of fire.
Only use self shielded illuminants to avoid hot parts, risk of fire
and exposure to UV-radiation.
MALFUNCTION
The appliance does not work at all.
Light is on but motor does not work.
Abnormal motor-smells.
Smear of oil.
Appliance vibrates.
Insufficient extracting capacity.
MEASURE
➢ Check the corresponding socket by
connecting it with another appliance.
➢ Check the fuse.
➢ The voltage is too low. Compare the
data on the model plate with the data
of your energy supplier.
➢ remove blockage.
➢ replace motor.
➢ replace motor
➢ seal the valve
➢ seal the connection with a suitable
material
➢ fix motor properly
➢ fix hood properly
➢ lower position of hood
➢ close the doors/windows
32