Herunterladen Inhalt Inhalt Diese Seite drucken

Multi-Protocol Operation; Mfx Protocol - LGB Mogul 20283 Bedienungsanleitung

Dampflok
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4

Multi-Protocol Operation

Analog Operation
This decoder can also be operated on analog layouts or areas of track that are
analog. The decoder recognizes alternating current (DC) and automatically adapts
to the analog track voltage. All functions that were set under mfx or DCC for analog
operation are active (see Digital Operation).
The built-in sound functions come from the factory inactive for analog operation.
Digital Operation
The built-in multi-protocol decoder can be used alternatively for operation with
a conventional DC locomotive controller (max. ±24 volts), mfx, or digital systems
adhering to the NMRA norm (DCC). The decoder automatically recognizes the mode
of operation, with priority for mfx.
Note: Digital protocols can influence each other. For trouble-free operation, we re-
commend deactivating those digital protocols not needed by using CV 50. Deactivate
unneeded digital protocols at this CV if your controller supports this function.
Note: Please note that not all functions are possible in all digital protocols. Several
settings for functions, which are supposed to be active in analog operation, can be
done under mfx and DCC.
Notes on digital operation
• The operating instructions for your central unit will give you exact procedures for
setting the different parameters.
• The values set at the factory have been selected for mfx in order to guarantee the
best possible running characteristics.
Adjustments may have to be made for other operating systems.
All manuals and user guides at all-guides.com

mfx Protocol

Addresses
• No address is required; each decoder is given a one-time, unique identifier (UID).
• The decoder automatically registers itself on a Central Station or a Mobile Station
Programming
• The characteristics can be programmed using the graphic screen on the Central
• All of the Configuration Variables (CV) can be read and programmed repeatedly.
• The programming can be done either on the main track or the programming track.
• The default settings (factory settings) can be produced repeatedly.
• Function mapping: Functions can be assigned to any of the function but-
DCC Protocol
Addresses
• Short address – long address – multiple unit address
• Address range:
• Every address can be programmed manually.
• Short or long address is selected by means of CV 29 (Bit 5).
• A multiple unit address that is being used deactivates the standard address.
• Address set at the factory: 03
Programming
• The characteristics can be changed repeatedly using the Configuration Variables (CV).
• The CV numbers and the CV values are entered directly.
• The CVs can be read and programmed repeatedly. (Programming is done on the
• The CVs can be programmed in any order desired. (PoM - Programming can be done
• The default settings (factory settings) can be produced repeatedly.
• 14 or 28/126 speed levels can be set.
• See the CV description for the DCC protocol for additional information.
We recommend that in general programming should be done on the programming track.
9
with its UID-identifier.
Station or also partially with the Mobile Station.
tons with the help of the 60212 Central Station (with limitations) and with the
60213/60214/60215/60216 Central Station (See help section in the Central Station).
1 – 127 for short address and multiple unit address,
1 – 10239 for long address
programming track.)
on the main track). PoM is not possible with CVs CV 1, 17, 18, and 29. PoM must be
supported by your central controller (Please see the description for this unit.).

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis