1500 Watt (cod. EH SAFE 15 AL ) / 2000 Watt (cod. EH SAFE 20 AL )
PLEASE NOTE: safe use of this equipment can only be ensured if the user complies with these directions. Users
must therefore keep these directions at hand at all times. Helios Safe Industry is an extremely versatile
infrared heater designed and constructed according to good practice and assembled with the best
components conforming to standards and/or certificates for ensuring safety during use.

1. TECHNICAL DATA

COD.
COLOUR
MICACEOUS
EHSAFE15AL
IRON
MICACEOUS
EHSAFE20AL
IRON
Mark : EHSAFE15AL
2. CONSTRUCTION
• Model of die-cast aluminum, oven epoxy powder coating
• Extra-pure, buffed, anodically oxidized aluminium parabolic reflector
• Front (ceramic, glass)
• Stainless steel AISI 316 Safety valve
• Silicone rubber seal
• Supply cable: length 1.5 m and; resistant to Temperature = 180° C
• Adjustable wall anchorage
WARNING
PLEASE NOTE: THIS HEATER IS SUITABLE FOR INSTALLATION IN EXPLOSIVE ATMOSPHERE CONDITIONS, CLASSIFIED
ZONE 2-22, PURSUANT TO DIRECTIVES 2014/34/UE AND 99/92 EC ATEX
ZONE 2-22 indicates that the atmosphere, which is normally not explosive during routine use, may, on rare
occasions, briefly become explosive (generally in the presence of a malfunction). The heater therefore cannot be
installed in zones other than those classed as ZONE 2-22. T2 indicates that the ignition temperature of the
flammable gasses of the classified zone must be higher than 300°C. The table below (from EN 13463-1) lists other
temperature classes.
Temperature Class
T1
T2
T3
T4
T5
T6
Read the various indications on the name plate. Conditions of use must correspond to the data indicated on the
name plate.
HELIOS ELECTRIC INFRARED IRK
SAFE INDUSTRY MODEL
OPERATING INSTRUCTIONS
VOLTAGE
POWER
HERTZ
240V
1500W
50/60
240V
2000W
50/60
Maximum Surface Temperature (°C)
450
300
200
135
100
85
MIN. HEIGHT
HEATED
FROM
AREA
CEILING
̃ 1 5 mq*
32 cm
̃ 2 0 mq*
32 cm
Mark : EHSAFE20AL
9
MIN.
PROTECTION
DISTANCE
RATING
FROM WALL
100 cm
66
100 cm
66