IMPORTANT NOTICE: TO PREVENT OVERHEATING OF THE BULB, THE EXTERNAL SURFACE OF
THE GLASS MUST ALWAYS BE KEPT CLEAN DISCONNECT POWER SUPPLY BEFORE CLEANING
•Connect Helios Safe Industry to a 220-240V power source, single-phase, according to the country in which
the appliance is used
• Helios Safe Industry must be connected to an earth connection system
• Check that the input power is appropriate for the electrical load to be installed
• THE APPLIANCE MUST ALWAYS BE INSTALLED HORIZONTALLY
• Do not cover or obstruct the appliance when operating
7.INSTALLATION/ SETTING AT WORK
These appliances can be installed, connected and set at work only by qualified persons. These persons
must be familiar with the types of anti-ignition protection, the regulations and the rules applying to the means
of production in the zone exposed to the risk of explosion. Check if the class (see the "Specifications" section
above and the label on the appliance) is suitable for specific use of the appliance.
8.INSTRUCTIONS FOR INSTALLATIONS/ASSEMBLY
The appliance must always be installed horizontally
Proceed in accordance with current regulations and national provisions and the pertaining instructions
provided by the manufacturer. Protect the appliances and cables to prevent all possible damage. Attach the
appliance to the wall at a minimum distance of 32 cm from the ceiling (see installation illustrations page 28-
29). The height at which the appliance is to be installed generally ranges from 2.0 m to a maximum 3.5 m.
Wall installation ensures an ideal position for optimal heating results, at a tilt angle of 45° (the appliance
must be perfectly horizontal). The appliance can also be installed on the ceiling, with chains (not supplied) at
a tilt angle of 45° to obtain the most efficient and wide area heated.
9.POSITIONING
Point the Helios Safe Industry reflector beam as required during wall installation. Normally the appliance is
tilted at approx. 45° with respect to the horizontal line. Never install Helios SafeIndustry on a flammable
surface or direct it toward a a flammable surface. The appliance must be positioned at a distance (line of
sight) of no less than 2.0 m, unencumbered, from objects such as cardboard, fabrics, curtains etc. or, likewise,
from glass panes.
Make sure that the bracket is correctly attached and fixed to the wall.
10.MAINTENANCE
CLEANING THE GLASS AND DUSTING THE APPLIANCE
(The appliance is sealed, also with lead.
Opening the appliance or tampering with it is not permitted).
Before cleaning/dusting the appliance, make sure the atmosphere has been
rendered non-explosive. When the atmosphere cannot be rendered non-explosive,
please note that operations in such environments can only be carried out by
qualified personnel, trained in regard to the specific risks. Such persons must also be
provided with protection devices (e.g. spark-proof tools etc.).
THIS SEAL CERTIFIES THAT THE PRODUCT HAS BEEN TESTED AND PERFECTLY WORKING AT THEIR ORIGIN, IT
SHOULD NOT BE CERTIFICA CHE IL PRODOTTO È STATO COLLAUDATO E PERFETTAMENTE FUNZIONANTE
ALL'ORIGINE E THAT SEAL SHOULD NOT BE REMOVED EXCEPT IN CASE OF MAINTENANCE BY AUTHORIZED
PEOPLE FROM STAR PROGETTI.
SAFETY VALVE MAINTENANCE
At the beginning of the operation period, check that there is not any dirty around the safety valve.
For the cleaning, use a brush. Operate also on the ring to move the seal piston to check its good
working. Warning: do not disassemble the safety valve for any reason.
Please check attachments "Operation and maintenance manual" of the Safety valve.