14. Glossary

R
Expert Mode: Supporting messages are displayed on
the screen for each individual action step.
R
Combo filter: Filter and dryer cartridge for removing
fine particles and moisture from the refrigerant.
R
PS2 stick:
Storage medium with PS2 connection; used in order
to perform software update of ACS 652, or to store
data from the internal memory of ACS 652 for data
management on a PC.
R
Recovery phase:
The refrigerant is removed from the vehicle air con-
ditioner using suction, cleaned and routed into the
internal vessel of the ACS 652. The refrigerant oil
collected in the process is drained into the used oil
bottle at the ACS 652.
R
Vacuum phase:
A vacuum is generated in the vehicle air conditioning
system. Measurement of the drop in pressure com-
mences as soon as the vacuum has been generated.
R
Fresh oil refill phase:
Fresh oil is added to the vehicle air conditioner.
R
UV dye refill phase:
A certain quantity of UV dye is added to the vehicle
air conditioner.
R
Filling phase:
A certain quantity of refrigerant is added to the
vehicle air conditioner.
R
Added oil quantity:
This is the quantity of oil previously recovered from
the air conditioning system plus the added oil quan-
tity entered.
i
The added oil quantity can only be set in automatic
mode. If the value is "0 ml", the quantity of compres-
sor oil added to the compressor corresponds to
the quantity of the recovered oil. If the value for the
added oil quantity is "20 ml", the quantity of compres-
sor oil added to the compressor corresponds to the
quantity of recovered oil plus 20 ml.
Robert Bosch GmbH
Glossary | ACS 652 | 63

15. Technical data

15.1

ACS 652

Property
Dimensions H x W x D
Weight
Operating voltage
Frequency
Workplace emission sound pressure level
as per EN ISO 11204
Refrigerant
Low-pressure gauge
High-pressure gauge
Capacity of internal refrigerant cylinder
Safety class
Power output
15.2

Ambient temperature

Property
Storage and transport
Operation
15.3

Air humidity

Property
Storage and transport
Operation
15.4

Electromagnetic compatibility

This product complies with the standards EN 61000-3-2
and EN 61000-3-3.
en
Value/range
1270 x 690 x 660 mm
110 kg
230 VAC ± 10 %
50/60 Hz
< 70 dB(A)
R134a
-1 bar – 16 bar ± 1 %
-1 bar – 40 bar ± 1%
27 l
IP 20
800 W
Value/range
-25 °C – 60 °C
-13 °F – 140 °F
10 °C – 50 °C
50 °F – 122 °F
Value/range
<75 %
<90 %
|
S P00 D00 158