Herunterladen Inhalt Inhalt Diese Seite drucken

Sensor; Internal Battery; Maintenance - Bosch IR LD 1.0 CO2 Bedienungsanleitung

Co2 leckanzeiger
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
en | 32 | IR LD 1.0 | Maintenance
7.2

Sensor

The IR LD 1.0 continuously moni-
tors the sensor for the correct
feedback signal. If the sensor is
defective, the unit will not be
properly conditioned during the
warm-up cycle and will not return
a correct feedback signal.
If the sensor does not return a
correct feedback signal, a warn-
ing symbol will be displayed (see
Fig. 17), indicating that the unit
requires immediate service: Con-
tact Bosch Customer Service for
instructions on how to return a
unit for service.
i
Unstable operation is an
indication that the sensor may
require replacement.
A
Fig. 17:
Component defect indication
SP01502142 | 14.03.2022
7.3

Internal battery

The IR LD 1.0 uses a rechargeable
lithium-ion battery. The battery is
rated to last several years, if prop-
erly maintained.
CAUTION
LITHIUM ION RECHARGEABLE
BATTERY INSIDE
Do not open the leak detector housing to access the
internal battery. This battery is not user replaceable.
IF DAMAGED
HANDLE WITH CARE
!
The IR LD 1.0 internal battery
is not user replaceable; contact
Bosch Customer Service
regarding battery-related
issues.
7.3.1

Maintenance

To help extend the life of the bat-
tery:
$
Maintain a 40–50% charge
during periods of non-use
greater than one month.
$
Store in an environment
with less than 75% relative
humidity (RH).
$
Only charge the IR LD 1.0
battery in ambient tem-
peratures of 0°C–45°C (32°
F–113° F).
$
Do not expose the battery
to temperatures above 60 °C
(140 °F)
$
Do not store the IR LD 1.0
with a fully charged battery
and/or at high temperatures;
doing so will significantly
reduce the life of the battery.
Bosch Automotive Service Solutions GmbH

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis