214 / 334
Bosch Rexroth AG
Information on this product
Power Unit:
•
Generating the %I
•
Controlling the medium-
frequency welding transformer
Fig. 7:General structure of an MF welding system with PRC7000
MF-welding
transformer
(PSG)
Secondary circuit
Primary circuit
PRC7000 |
*)
Options for welding current measurement:
•
Current sensor in the secondary circuit of the
PSG
•
Separate secondary circuit sensor
•
Current sensor in the primary circuit of the
PRC
to constant current
regulation (KSR)
(necessary for the optio
Current sen
*)
sor
Electrodes
Mains
Timer module:
•
•
•
•
•
•
R911172834 / 02
Voltage tapping
nal UI regulation)
Communication with robot/
PLC
Communication with pro
gramming device
(PRI7000)
via Ethernet
via USB
WIC Port 1 and Port 2
Additional modules