Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications - Kärcher WPD 50 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Operating voltage
Connected load
Minimum power protection
Water input pressure
Water supply temperature
Water output (depending on feed pressure and filter status)
Unchilled water
Chilled water
Temperature of chilled water, max.
Ambient temperature
Width
Depth
Height
Weight
Description
Description
Replacement filter
(Active-Pure-Filter) Removal of negative taste or odour producing substances (e.g. chlorine), retention of heavy metals
AC WPD Range
and contamination from the supply line system.
UV-lamp
OSRAM GERMICIDAL PURITEC HNS G5 11W or Philips TUV 11W T5
Description
Description
Cleaning kit
For intake of the chemical detergent (Bevi Tabs alkali). Reusable.
Bevi tabs alkaline
Chemical detergent for semi-annual internal cleaning of the WPDs, packaging unit 1x 10 tabs
Description
Description
RM 735
Effective neutral disinfectant. Acts as a bactericide, fungicide and conditionally virucide. 1 x 20 ml.
CA 30 R
Ready-to-use surface cleaner, 0.5 l spray bottle
Spray head for surface
With the initial order of CA 30R this reusable spray head is required for the spray bottle.
cleaner
Spray bottle, RM 735
Spray bottlle 250 ml, to start the disinfectant.
Fill 20 ml RM 735 into the bottle and top the bottle off with water.
WARNING
Health hazards on account of improperly repaired appli-
ance. The appliance may only be repaired by trained
and skilled personnel.
Faults / display
Appliance does not dispense water, but shows
"Ready".
All buttons are illuminated.
The device does not function / none of the buttons
is illuminated.
Water dispenser does not provide cooled water,
even though cooled water was selected
Continuous interval beeping sound

Technical specifications

Consumables
Detergent for chemical cleaning
Detergent for exterior cleaning of the device
Troubleshooting
Before doing any work on the machine:
 Set the appliance switch to "0".
 Pull out the mains plug.
 Shut off water supply.
Possible cause
Water supply interrupted.
Voltage supply is interrupted.
The appliance is switched off.
Blown fuse.
Cooling module has not reached its nom-
inal temperature.
UV filter lamp is defective.
EN
V/~/Hz
W
A
MPa (bar)
°C
l/h
l/h
°C
°C
mm
mm
mm
kg
Remedy
Ensure adequate water supply, check locking devices.
If the fault persists, contact customer service.
Insert the mains plug into the socket.
Set the appliance switch to "I".
Pull out the fuse holder next to the power switch, replace fuse with fuse of same
rating.
If the fuse blows again, switch off the device and call Service.
Wait 20 to 40 minutes and check it again.
If the cooling function exhibits permanent failure:
Set the appliance switch to "0".
Inform service.
Replace the lamp of the UV filter.
5
-
WPD 50
220 - 240 / 50
230
6
0.15...0.6 (1.5...6)
5...30
60...90
60...90
5
10...35
300
440
395
18
Order No.
2.643-305.0
6.640-634.0
Order No.
2.643-941.0
6.295-891.0
Order No.
6.295-476.0
6.295-686.0
6.295-723.0
6.295-575.0
13