Herunterladen Inhalt Inhalt Diese Seite drucken

Siemens 5WG1 372-5EY01 Bedienungsanleitung Seite 57

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Note:
After a time adjustment, only pulses, which are programmed at
least 1 minute after the time adjustment, are carried out.
4. Pulse Program for Time Delayed Switch-OFF
A switch-OFF time e.g. at 8.0 and 10 secs. can be achieved by:
1. Programming a switch-OFF time eg.g. 8
2. Additional programming of a simultaneous pulse switching time of 10 secs.
duration.
OFF p
00
1. Switch-OFF time e.g. 8
2. Additional pulse ON (o) at 8
00
for
10 secs duration
3. Effective at 8
00
10 secs.
switch OFF.
Note:
After time adjustment, only pulses, which are programmed at least 1
minute after the time adjustment are carried out.
5. Channel Block Formation
If not all memory locations are to be used, we recommend you dispense with
channel block formation when programming switching times.
This provides advantages when changing or cancelling individual switching
commands.
15.0 Glossary
What does automatic operation (Auto) mean?
00
(Chapter 7.1)
What is automatic return?
Program recan?
What does entry correction mean?
What does weekday block formation mean?
What does channel block formation mean?
57
The cursor is below Auto. Current time is displayed.
The switching sequence of the time switch is determined by the stored
switching times.
When in the interrogation or programming mode, if no button is used for a
long time, the display reverts automatically, after approx. 40 secs. to automa-
tic operation. The product then takes up the switching status specified by the
program.
This results in the time switch checking the stored program and implementing
the correct switching condition.
In the event of wrong entry during programming, by pressing the CL button,
the entry can be cancelled and immediately corrected.
Simultaneous programming at one switching time e.g. 6
of the week e.g. Monday, Tuesday and Friday.
Only one memory lacation is used.
Simultaneous programmed switching times, which are effective in several
channels, take up only one memory location.
Advantage: Faster programming of the switching times.
00
ON on several days

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

5wg1 372-5ey02

Inhaltsverzeichnis