Sweep characteristic
Control voltage
Maximum sweep-frequency
Maximum
modulation frequency
(Phase-sweep < 5 %)
Maximum permissible voltage
ENVIRONMENTAL CONDITIONS
Ambient temperature
—
reference value
—
nominal operating temperature range
~— temperature range for transport and
storage
Operating position
Supply voltage
—
reference value
—
nominal values
—
nominal operating range
Frequency
—
tolerance
Consumption
CABINET
Protection class (see VDE 0411)
Protection type (see DIN 40 050)
Overall dimensions
~— height
—
width
—
depth
Weight
: linear
: 0.5 V per interval of the FREQUENCY dial, e.g. from 3 to 4.
With a positive-going control voltage, a sweep to higher
frequencies is obtained, and with a negative-going.control
voltage, a sweep to lower frequencies.
: > 500 Hz, at sweep-range = 2 decades and triangular
control-signal.
: 50 kHz (3 dB limit for frequency sweep at constant sinewave
control-voltage).
:£15V
: 23 degC
: +5 to +40 deg C
: —40 to +70 deg C
: optional
: a.c. mains
: 230 V
2115 V, 230 V
: £15 % of the selected nominal value
: 50 to 100 Hz
745%
: 30W
: Class 1, protective conductor
: IP 20
: 145 mm
: 240 mm
: 300 mm
: 3.6 kg