12.1 Altering the operating programming enable

Procedure:
During normal operation, press the
least 3 s.
OPrG (Operating Programming) is displayed.
After approximately 2 s the display changes and the actual setting is displayed:
Free (programming enabled) or Loc (programming disabled).
Within approx. 3 s the setting can be changed to Loc or Free by pressing
If
or
is not pressed for approximately 3 s or longer, then the displayed setting is
accepted. If a setting has been altered, then ProG (programming) is displayed for ap-
proximately 2 s. This means the changed setting is stored in the HDA 5500. Afterwards
the display returns to normal operation.
3 s
mode
Press both arrow
keys simultaneously
and hold down for 3 s

12.2 Altering the main programming enable

The main programming enable can only be altered when switching on the HDA 5500. If the
HDA 5500 is already in operation, then the supply voltage must first be switched off or the
HDA 5500 must be disconnected from the supply voltage.
Procedure:
When switched off, press both arrow keys simultaneously and hold down.
Switch on or connect the supply voltage and at the same time continue to hold down the
arrow keys for at least 3 s.
MPrG (Main Programming) is displayed.
After approximately 2 s the display changes and the actual setting is displayed:
Free (programming enabled) or Loc (programming disabled).
Within approximately 3 s the setting can be changed to Loc or Free by pressing
the
or
key.
If
or
have not been pressed for approximately 3 s or longer, then the displayed
setting is accepted. If a setting has been changed, then ProG (Programming) is dis-
played for approximately 2 s. This means the changed setting is stored in the HDA 5500.
Afterwards the display returns to normal operation.
mode
3 s
Press both arrow
keys simultaneously
and hold down.
Switch on supply
voltage (hold down
keys for 3 s)
All manuals and user guides at all-guides.com
and
2 s
Display
(release
arrow keys)
Use
2 s
Display
(release
arrow keys)
Use
keys simultaneously and hold down for at
mode
to change setting
or
= programming enabled
FrEE
Loc
= programming disabled
mode
to change setting
or
= programming enabled
FrEE
Loc
= programming disabled
User Manual
or
.
Displays
measured value
3 s
Displays
measured value
3 s
- 18 -