Herunterladen Inhalt Inhalt Diese Seite drucken

NISBETS ESSENTIALS DF524 Bedienungsanleitung Seite 6

Wasserboiler
Vorschau ausblenden Andere Handbücher für DF524:
Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 20
EN
De-scaling
For the best water quality, Nisbets Essentials recommend that a water filter is installed to the mains water
supply, particularly in hard water areas. Doing so will reduce the build up of limescale and contaminants in the
water tank thus maintaining energy efficiency and prolonging the life of the appliance.
To de-scale the appliance:
1. Turn off and disconnect the appliance from the power
supply.
2. Remove the cleanser inlet cap. Then pour a solution of
de-scaler and water into the appliance via the inlet.
Note: Always use a suitable de-scaler and follow the manufacturer's instructions on the length of time
required to soak, water temperature and on how to dispose of the solution safely.
3. Drain the solution and discard safely.
4. Re-start the appliance and let it run 2 or 3 boiling cycles to flush out the system and remove any de-scaler
residue. Empty the appliance afterwards.
5. The appliance is now ready for use.
IMPORTANT: Failure to de-scale or maintain will invalidate your guarantee.
Troubleshooting
A qualified technician must carry out repairs if required.
Fault
The appliance is
The unit is not switched on
not working
Plug or lead is damaged
Fuse in the plug has blown
Mains power supply fault
"ELL" on Display
It is normal in case of the first time filling
Water shortage
"Er1" on Display
Water supply
"Er2" on Display
Heating element is faulty
"ErH" on Display
Thermoprobe for the water
heating is faulty
6
DF524_ML_A5_v2_20230407.indb 6
DF524_ML_A5_v2_20230407.indb 6
Probable Cause
Check the unit is plugged in correctly and switched on
Replace plug or lead
Replace the fuse
Check mains power supply
Check water supply is normal and water inlet hose is
not blocked. If problem persists, consult a qualified
Technician
Check water supply is normal and water inlet hose is
not blocked. If problem persists, consult a qualified
Technician
Consult a qualified Technician
Consult a qualified Technician
Cleanser inlet cap
Solution